HP FDDI 9000 FDDI/9000 EISA Adapter Release Notes - Page 25

Table 1-6, PHNE_15667, Table 1-5, PHNE_16503, Continued

Page 25 highlights

Table 1-5 Table 1-6 FDDI/9000 EISA Adapter Release Notes Patches and Fixes in Version B.11.00.07 PHNE_16503 (Continued) Symptom 3. lanadmin displays Operation Status as "down(2)" even if the interface is up. 4. System hangs under heavy network traffic over EISA FDDI. Defect 3. The driver was not updating the operation status field in its data structure after the initialization was complete. As a result, incorrect status was displayed by the lanadmin(1M) command. 4. Under heavy network load, the driver fails t enqueue packets due t lack of transmit descriptors. In such a condition the driver is supposed to free the buffers associated with the packet. This was not being done. As a result, kernel runs out of memory leading to a system hang. PHNE_15667 Symptom Defect 1. The EISA FDDI interface may hang after logging the message "Waited for stat2_ine4 but it never came" to syslog. 1. A software reset mechanism was introduced in the EISA FDDI driver to work around the hardware defects in the Motorola FDDI System Interface (FSI) chip. This mechanism did not detect all the circumstances under which the card had t be reset. 2. When an attempt is made to change the MAC address of the card using lanadmin(1M), the link is unusable for up to 10 seconds and the MAC address remains unchanged. 2. The MAC address of the card cannot be changed. Users were not prevented from attempting to do this. 3. Under certain conditions, too many informative driver messages are logged to syslog, causing it to overflow. 3. SMT and other informative messages were incorrectly sent to syslog instead of the NetTL log. Chapter 1 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Chapter 1
25
FDDI/9000 EISA Adapter Release Notes
Patches and Fixes in Version B.11.00.07
3.
lanadmin
displays Operation
Status as “down(2)” even if the
interface is up.
3. The driver was not updating the
operation status field in its data
structure after the initialization was
complete. As a result, incorrect status
was displayed by the
lanadmin(1M)
command.
4. System hangs under heavy network
traffic over EISA FDDI.
4. Under heavy network load, the
driver fails t enqueue packets due t
lack of transmit descriptors. In such a
condition the driver is supposed to free
the buffers associated with the packet.
This was not being done. As a result,
kernel runs out of memory leading to a
system hang.
Table 1-6
PHNE_15667
Symptom
Defect
1. The EISA FDDI interface may hang
after logging the message
“Waited
for stat2_ine4 but it
never came”
to syslog.
1. A software reset mechanism was
introduced in the EISA FDDI driver to
work around the hardware defects in
the Motorola FDDI System Interface
(FSI) chip. This mechanism did not
detect all the circumstances under
which the card had t be reset.
2. When an attempt is made to change
the MAC address of the card using
lanadmin(1M)
, the link is unusable
for up to 10 seconds and the MAC
address remains unchanged.
2. The MAC address of the card cannot
be changed. Users were not prevented
from attempting to do this.
3. Under certain conditions, too many
informative driver messages are logged
to syslog, causing it to overflow.
3. SMT and other informative
messages were incorrectly sent to
syslog instead of the NetTL log.
Table 1-5
PHNE_16503
(Continued)
Symptom
Defect