HP Integrity rx6600 Windows Integrity Management Agents Reference - Page 62
Error while reading the remote CC's XIN Error Mask register Probable Cause: CC
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Event ID Event Severity Event Description 9390 Error MPON failed to release. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcMponFailed 9390 in HPIFPTRAP.MIB. 9391 Error Dillon failed to reset. Probable Cause: Hardware failure. Recommended Action: Fix the hardware, pdh riser or cell. SNMP Trap: hpevtPdhcDillonResetFailed - 9391 in HPIFPTRAP.MIB. 9392 Error DMD clock is not running. Probable Cause: A hardware fault has occurred. Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board, Cell Power Board and PDH Daughtercard. SNMP Trap: hpevtPdhcDmdClockFailed - 9392 in HPIFPTRAP.MIB. 9394 Error All cpus on the Cell are scheduled to be deconfigured Probable Cause: All cpus on the cell have been scheduled for deconfiguration. On the next reset, the cell will no longer be operational; system firmware will deconfigure all the cpus and this cell will not be part of a partition. This action is not recommended. To recover, the NVRAM on the PDH card must be cleared, the cell power cycled, and defaults restored from disk. SNMP Trap: hpevtAllCpusDeconfOnCell - 9394 in HPIFPTRAP.MIB. 9403 Error A read error occurred while dumping the routing registers Probable Cause: Fabric Read Error. Recommended Action: Check XBC, CC, links, etc. SNMP Trap: hpevtFabricLogRoutingRdErr - 9403 in HPIFPTRAP.MIB. 9412 Error Failed to disable the CC to CC link Probable Cause: Failure to read or write CC CSRs. Recommended Action: Contact HP Support personnel to check the Check CC. SNMP Trap: hpevtFabricLinkRendezDisableErr - 9412 in HPIFPTRAP.MIB. 9417 Warning Power has been removed from AC input A0. Probable Cause: A power source has been removed from the chassis. SNMP Trap: hpevtAcDeletedA0 - 9417 in HPIFPTRAP.MIB. 9418 Warning Power has been removed from AC input A1. Probable Cause: A power source has been removed from the chassis. SNMP Trap: hpevtAcDeletedA1 - 9418 in HPIFPTRAP.MIB. 9419 Warning Power has been removed from AC input B0. Probable Cause: A power source has been removed from the chassis. SNMP Trap: hpevtAcDeletedB0 - 9419 in HPIFPTRAP.MIB. 9420 Warning Power has been removed from AC input B1. Probable Cause: A power source has been removed from the chassis. SNMP Trap: hpevtAcDeletedB1 - 9420 in HPIFPTRAP.MIB. 9428 Warning Failed to disable the XIN link during a failed link init Probable Cause: Have your HP Support Representative check the Coherency Controller SNMP Trap: hpevtFabricCc2CcLinkDisableErr - 9428 in HPIFPTRAP.MIB. 9430 Error Error copying the routing registers to the local port Probable Cause: XBC access failure. Recommended Action: Check XBC, check links, check backplane, check CC. SNMP Trap: hpevtFabricISREarlyCopyRoutingErr - 9430 in HPIFPTRAP.MIB. 9431 Warning Error while reading the remote CC's XIN Error Mask register Probable Cause: CC access failure. Recommended Action: Contact HP Support personnel to check the CC. SNMP Trap: hpevtFabricClrLinkInitBitErrMaskRd - 9431 in HPIFPTRAP.MIB. 9432 Warning Error clearing the init packet received bit in the XIN error mask Probable Cause: CC access failure. Recommended Action: PDC Reviewed alert level for SR - 9/6/03 CC. SNMP Trap: hpevtFabricClrLinkInitBitErrMaskWr - 9432 in HPIFPTRAP.MIB. 9433 Warning Failed to read the XBC's Port Status register Probable Cause: fabric access failure Recommended Action: Check XBC, Check CC, Check backplane SNMP Trap: hpevtFabricPortPairRdPstatusErr - 9433 in HPIFPTRAP.MIB. 62 Management Agents Event Tables