HP Integrity rx6600 Windows Integrity Management Agents Reference - Page 70
Failed to read the XBC CSR High Severity Error Log State Probable Cause: Fabric
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 70 highlights
Event ID Event Severity Event Description 9780 Warning Failed to read the XBC CSR Error Status register Probable Cause: Fabric Access Failure. Likely hardware problem. Look for additional chassis codes to further isolate the error. SNMP Trap: hpevtFabricErrsCsrLogClrRdSlicesErr - 9780 in HPIFPTRAP.MIB. 9781 Warning Failed to copy the XBC CSR Error Symbol01 Block Probable Cause: Fabric Access Failure; Possibly an invalid destination address. Check hardware, Contact HP Support SNMP Trap: hpevtFabricErrsCsrLogClrCopyBlk0Err - 9781 in HPIFPTRAP.MIB. 9782 Warning Failed to copy the XBC CSR Error Symbol23 Block Probable Cause: Fabric Access Failure; Possibly an invalid destination address. Check hardware, Contact HP Support SNMP Trap: hpevtFabricErrsCsrLogClrCopyBlk2Err - 9782 in HPIFPTRAP.MIB. 9783 Warning Failed to reset the XBC Low Severity Error Log State Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane SNMP Trap: hpevtFabricXbcLoStateResetErr - 9783 in HPIFPTRAP.MIB. 9784 Warning Failed to clear the XBC Low Severity Log Symbol 01 Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Backplane SNMP Trap: hpevtFabricClrXbcSym01Failure - 9784 in HPIFPTRAP.MIB. 9785 Warning Could not determine if there is a new XBC CSR Low Severity error Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane SNMP Trap: hpevtFabricClrXbcIsLoCsrErrErr - 9785 in HPIFPTRAP.MIB. 9786 Warning Failed to read the XBC CSR Low Severity Error Log State Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane SNMP Trap: hpevtFabricClrXbcRdLoLogStateErr - 9786 in HPIFPTRAP.MIB. 9787 Warning Failed to reset the XBC Low Severity Error Log State Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane SNMP Trap: hpevtFabricXbcHiStateResetErr - 9787 in HPIFPTRAP.MIB. 9788 Warning Could not determine if there is a new XBC CSR High Severity error Probable Cause: Check XBC, Flex Cables, Backplane Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane SNMP Trap: hpevtFabricClrXbcIsHiCsrErrErr - 9788 in HPIFPTRAP.MIB. 9789 Warning Failed to read the XBC CSR High Severity Error Log State Probable Cause: Fabric Access Failure. Recommended Action: Contact HP Support personnel to check the XBC, Flex Cables, Backplane SNMP Trap: hpevtFabricClrXbcRdHiLogStateErr - 9789 in HPIFPTRAP.MIB. 9801 Error An error occurred while enabling hashing in the platform cache Probable Cause: An error return status. This could happen if the tree was corrupted or there was an error verifying the hashing setting. Recommended Action: reset the partition SNMP Trap: hpevtPlatformCacheHashingError - 9801 in HPIFPTRAP.MIB. 9827 Warning The XBC CSR is not a valid CSR address Probable Cause: Invalid CSR address, possible firmware defect. Recommended Action: Capture complete live logs and contact HP Support representative. SNMP Trap: hpevtFabricXbcWriteableInvalidCsr - 9827 in HPIFPTRAP.MIB. 9832 Error It indicates loss of cell connectivity in the partition. Probable Cause: It will lead to cells performing RESET_FOR_RECONFIG after getting the error logs. SNMP Trap: hpevtMcCellsLostConnection - 9832 in HPIFPTRAP.MIB. 9849 Error Error building cell-level FW device tree Probable Cause: Data field displays the status of creating the cell level device tree for use by firmware. See previous errors already reported. SNMP Trap: hpevtBuildErrCellDevTree - 9849 in HPIFPTRAP.MIB. 70 Management Agents Event Tables