Table 1-5 Environmental Specifications system processing unit with hard disk

Page 12 highlights

Table 1-5 Environmental Specifications (system processing unit with hard disk) (continued) Parameter Value Operating humidity 15% to 80% relative (noncondensing) Storage humidity 90% relative (noncondensing) at + 65˚ C Acoustic Noise Emission (ISO 9296) Sound Power Level1 LwAd =7.5 B Sound Pressure Level LpAm =57.5 dB Altitude Operating altitude 0 to 3000 m (10,000 ft.) max Storage altitude 0 to 4572 m (15,000 ft.) max 1 Typical configuration at room temperature (25˚C). Table 1-6 Physical and Environmental Specifications Condition Typical Heat Release Voltage 200-240 Vac Airflow, Nominal Description Watts CFM m³/hr2 Airflow, Maximun at 35ºC1 CFM m³/hr2 Minimum 433 346 Configuration Maximum 1633 346 Configuration Typical 998 346 Configuration 588 441 750 588 441 750 588 441 750 Weight Overall System Dimensions (W X D X H Server Rack Pedestal Rack Pedestal 150 lbs 120-150 (68.04 lbs. kg) max Max: 15.5 kg. (34 lbs.) 154 lbs. (6909 kg.) 184 lbs. (83.5 kg.) 69.6 cm (27.4 in) x 44 cm (17.32 in) x 30.58 cm (12.04 69.3 cm (27.3 in) x 48.9 cm (19.3 in) x 42.2 cm (16.7 in) in) ASHRAE Class 1 Air Flow Diagram Cooling Scheme (F - R) Minimum (1x) Itanium 1.4G/12M or 1.6G/18M or 1.6G/24M Configuration CPUs, (4x) 4GB DDRII DIMM memory, (0x) SAS Hard Drives, (0x) PCI/PCI-X/PCIe added to public I/O cards. Maximum (4x) 1.6G/24M CPUs, (48x) 4GB DDRII DIMM Configuration memory, (16x) SAS Hard Drives, (8x) PCI/PCI-X/PCIe added to public I/O cards. Front to Rear (F-R) Typical Half-loaded configuration: (2x) Itanium Configuration 1.4G/12M or 1.6G/18M or 1.6G/24M CPUs, (24x) 4GB DDRII DIMM memory, (8x) SAS Hard Drives, (4x) PCI/PCI-X/PCIe added to public I/O cards. 1 Derate maximum dry bulb temperature 1oC/300 m above 900 m. 2 m3/hr=1.7 x CFM 12 System Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

Table 1-5 Environmental Specifications (system processing unit with hard disk)
(continued)
Value
Parameter
15% to 80% relative (noncondensing)
Operating humidity
90% relative (noncondensing) at + 65˚ C
Storage humidity
Acoustic Noise Emission (ISO 9296)
LwAd =7.5 B
Sound Power Level
1
LpAm =57.5 dB
Sound Pressure Level
Altitude
0 to 3000 m (10,000 ft.) max
Operating altitude
0 to 4572 m (15,000 ft.) max
Storage altitude
1
Typical configuration at room temperature (25˚C).
Table 1-6 Physical and Environmental Specifications
Overall System
Dimensions
(W X D X H
Weight
Condition
Airflow, Maximun at
35ºC
1
Airflow, Nominal
Typical
Heat
Release
Pedestal
Rack
Pedestal
Rack
Server
Voltage
200-240
Vac
69.3 cm
(27.3 in)
x 48.9
cm (19.3
in) x 42.2
cm (16.7
in)
69.6 cm
(27.4
in) x 44
cm
(17.32
in) x
30.58
cm
(12.04
in)
Max:
15.5 kg.
(34 lbs.)
150 lbs
(68.04
kg)
max
120-150
lbs.
m³/hr
2
CFM
m³/hr
2
CFM
Watts
Description
154 lbs.
(6909
kg.)
750
441
588
346
433
Minimum
Configuration
184 lbs.
(83.5
kg.)
750
441
588
346
1633
Maximum
Configuration
750
441
588
346
998
Typical
Configuration
(1x) Itanium 1.4G/12M or 1.6G/18M or 1.6G/24M
CPUs, (4x) 4GB DDRII DIMM memory, (0x) SAS
Hard Drives, (0x) PCI/PCI-X/PCIe added to
public I/O cards.
Minimum
Configuration
Air Flow Diagram Cooling Scheme
(F - R)
Front to Rear (F-R)
ASHRAE
Class 1
(4x) 1.6G/24M CPUs, (48x) 4GB DDRII DIMM
memory, (16x) SAS Hard Drives, (8x)
PCI/PCI-X/PCIe added to public I/O cards.
Maximum
Configuration
Half-loaded configuration: (2x) Itanium
1.4G/12M or 1.6G/18M or 1.6G/24M CPUs, (24x)
4GB DDRII DIMM memory, (8x) SAS Hard
Drives, (4x) PCI/PCI-X/PCIe added to public I/O
cards.
Typical
Configuration
1
Derate maximum dry bulb temperature 1oC/300 m above 900 m.
2
m
3
/hr=1.7 x CFM
12
System Specifications