HP LH4r hp lp 2000r and virtual array config guide — for Microsof - Page 4

Server, Network

Page 4 highlights

lp2000r2k71/74 Microsoft® and HP Certified Server Configuration Parameter Server I/O card slot Network interfaces Boot device Specification PCI slot 2, HP D8602B HBA for shared storage Embedded NICs for both intra-cluster (heartbeat) and client LANs Embedded SCSI Intra-Cluster (Heartbeat) LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification HP D5954A crossover cable, or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. One Embedded NIC - LAN A, or any model that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. For embedded NIC, hptxnt5.sys, version 4.02.27, or later (driver obtained from Navigator CD-ROM L.20.00, or later). For other NICs, any vendor-supported driver. Client LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification Any LAN One Embedded NIC - LAN B, or any model that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. Vendor-supported driver If the NIC used is the same type as that of the intra-cluster LAN, then the client LAN driver must be the same as that of the intra-cluster LAN. 3/8/02 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

lp2000r2k71/74
3/8/02
4
Microsoft
°
and HP Certified Server Configuration
Parameter
Specification
Server
I/O card slot
PCI slot 2, HP D8602B HBA for shared storage
Network interfaces
Embedded NICs for both intra-cluster (heartbeat) and client LANs
Boot device
Embedded SCSI
Intra-Cluster (Heartbeat) LAN Configuration
Parameter
Specification
Network
Connection
HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication.
It may
not be used for client communication.
NIC
Quantity
One
Model
Embedded NIC – LAN A,
or any model that is on both the HP Tested Products List and the Microsoft
Hardware Compatibility List.
Driver
For embedded NIC, hptxnt5.sys, version
4.02.27, or later
(driver obtained from Navigator CD-ROM L.20.00, or later).
For other NICs, any vendor-supported driver.
Client LAN Configuration
Parameter
Specification
Network
Connection
Any LAN
NIC
Quantity
One
Model
Embedded NIC – LAN B,
or any model that is on both the HP Tested Products List and the Microsoft
Hardware Compatibility List.
Driver
Vendor-supported driver
If the NIC used is the same type as that of the intra-cluster LAN, then the client
LAN driver must be the same as that of the intra-cluster LAN.