HP LH4r hp netserver lc 2000 netraid-4m config guide — for Micros - Page 3

Enclosure, Cables, Power distribution, Server

Page 3 highlights

lc2000nt4m Shared Storage Configuration Parameter SCSI ID Channels RAID levels Containers Configuration options Enclosure Disk drives Number of cabinets Model Status SCSI ID Disk SCSI IDs Cables SCSI Power distribution Layout Specification 6, 7 0, 1, 2, 3 All fault-tolerant RAID types supported by controller: 1, 5, 10 (stripe set of mirror sets RAID 0/1), 50 (stripe set of RAID-5 sets), volume set of mirror sets, volume set of RAID-5 sets Single-level or multi-level Must be fault-tolerant Eight, maximum, per cluster Write cache disabled Clustering enabled Domain validation enabled Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in a diskset, on a SCSI channel, or in a cluster. Up to eight Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 (fixed) Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoft® and HP Certified Server Configuration for Ultra2 Models Parameter Server I/O card slot Network interfaces Boot device Specification PCI slot 1, NetRAID-1M local storage controller PCI slot 5, NetRAID-4M shared storage controller PCI slot 3, Client LAN, model D5013B NIC NetRAID-1M local storage controller Microsoft® and HP Certified Server Configuration for Ultra3 Models Parameter Server I/O card slot Specification PCI slot 5, NetRAID-4M shared storage controller PCI slot 6, NetRAID-1M local storage controller 1/28/02 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lc2000nt4m
1/28/02
3
Shared Storage Configuration
Parameter
Specification
SCSI ID
6, 7
Channels
0, 1, 2, 3
RAID levels
All fault-tolerant RAID types supported by controller:
1, 5, 10 (stripe set of
mirror sets RAID 0/1), 50 (stripe set of RAID-5 sets), volume set of mirror sets,
volume set of RAID-5 sets
Containers
Single-level or multi-level
Must be fault-tolerant
Eight, maximum, per cluster
Configuration options
Write cache disabled
Clustering enabled
Domain validation enabled
Enclosure
Disk drives
Any HP drive supported by storage enclosure.
Any combination of HP disk
models is allowed in a diskset, on a SCSI channel, or in a cluster.
Number of cabinets
Up to eight
Model
Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0–3, 8–15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page
5
.
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page
6
.
Microsoft
°
and HP Certified Server Configuration for Ultra2 Models
Parameter
Specification
Server
I/O card slot
PCI slot 1, NetRAID-1M local storage controller
PCI slot 5, NetRAID-4M shared storage controller
Network interfaces
PCI slot 3, Client LAN, model D5013B NIC
Boot device
NetRAID-1M local storage controller
Microsoft
°
and HP Certified Server Configuration for Ultra3 Models
Parameter
Specification
Server
I/O card slot
PCI slot 5, NetRAID-4M shared storage controller
PCI slot 6, NetRAID-1M local storage controller