HP LH4r HP Netserver LH 4 Rack Storage/12FC Cluster Config Guide for Windows - Page 2

Storage - netserver lh4

Page 2 highlights

Operating system Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots Default Boot Order M/S Certified Configuration Storage Microsoft Windows NT Server 4.0, Enterprise Edition SP6a or later HP NetServer LH4 400, 450, 500, 550, 700 MHz 2 - 4 4.06.22 PS or later (400 - 550 MHz) 4.06.32 PS or later (700 MHz) Any size 128 MB minimum. Must be HP. 3 required, 4 for redundancy See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-1, PCI-2, PCI-3, PCI-4, PCI-5, PCI-6, PCI-7, PCI-8 P1 - Shared storage FC HBA (D8602A) P3 - Client LAN (D5013B) P4 - Intra-cluster (Heartbeat) LAN (D5013B) P7 - Local storage (NetRAID-1Si) Local Controller Drivers Cabinets (Physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI Ids May use embedded SCSI, embedded DAC, NetRAID-3Si or NetRAID-1Si. For embedded SCSI, use sym_hi.version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP. Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared HP Rack Storage/12FC Host Bus Adapter Model No. of HBAs Driver RAID level Cabinet RAID arrays No. of cabinets FC Array Cards Required HP D8602A 1 Hhba5100.sys 1.12 or later 0, 1, 3, 5 Not more than 8 physical drives per logical array and not more than 8 LUNs are permitted per Rack Storage/12FC and Rack Storage/12 combination in a cluster. 1 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Operating system
Service pack
Microsoft Windows NT Server 4.0, Enterprise Edition
SP6a or later
SPU
Model
HP NetServer LH4
Clock speed
400, 450, 500, 550, 700 MHz
No. of CPUs
2 – 4
BIOS version
4.06.22 PS or later (400 – 550 MHz)
4.06.32 PS or later (700 MHz)
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
No. of power supplies
3 required, 4 for redundancy
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind
the server’s default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded A, Embedded B, PCI-1, PCI-2, PCI-3,
PCI-4, PCI-5, PCI-6, PCI-7, PCI-8
M/S Certified
Configuration
P1 – Shared storage FC HBA (D8602A)
P3 – Client LAN (D5013B)
P4 – Intra-cluster (Heartbeat)
LAN (D5013B)
P7 – Local storage (NetRAID-1Si)
Storage
Local
Controller
May use embedded SCSI, embedded DAC, NetRAID-3Si or
NetRAID-1Si.
Drivers
For embedded SCSI, use sym_hi.version 4.12 or later.
For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap or
fixed)
Must be HP.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
Required
Host Bus Adapter
Model
HP D8602A
No. of HBAs
1
Driver
Hhba5100.sys 1.12 or later
RAID level
0, 1, 3, 5
Cabinet
RAID arrays
Not more than 8 physical drives per logical array and not more than 8
LUNs are permitted per Rack Storage/12FC and Rack Storage/12
combination in a cluster.
No. of cabinets
1
FC Array Cards