HP LH4r HP Netserver LP 2000r FC Config Guide for Windows 2000 Advanced Serve - Page 2

Storage

Page 2 highlights

Intra-cluster (Heartbeat) LAN Power source System software: Navigator version Operating System Service Pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots Default Boot Order Microsoft® and HP Certified Configuration Embedded NIC with crossover cable, or, configure as a VLAN through an Ethernet switch. See Intra-cluster LAN below. Direct from power mains, power conditioner or uninterruptible power supply (UPS) using any power conditioner or UPS. Redundant power distribution units (PDU's) are strongly recommended. L.20.00 or later Microsoft Windows® 2000 Advanced Server SP1 or later HP NetServer LP2000r 1 GHz 2 4.06.16 or later Any size 256 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI P1 - Local storage (NetRAID-1M) P2 - Shared Storage FC HBA (D8602B) Booted from NetRAID-1M Storage Local Controller Driver Cabinets (Physical drive location) Disk drives SCSI bus SCSI Ids Shared May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M, or NetRAID-2M For SPOFless, recommend NetRAID-xM with internal drives in RAID5, or another fault-tolerant RAID level. For embedded SCSI, use SYM_U3.SYS, version 5.07.00 or later. For NetRAID-xSi, use MRAID35X.SYS, version 2.66 or later. For NetRAID-xM, use MRAID2K.SYS version 5.20 (Navigator L.20.00 or later) SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. Must be HP (hot swap or fixed). Any HP cables that meet SCSI specifications and any SCSI bus speed. Any HP Rack Storage/12FC Required - D5991A Host Bus Adapter Model No. of controllers Driver HP Fibre Channel Host Bus Adapter - HP D8602B 1 HP D8602B - AFCW2K.SYS 3.0.3245.1 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

2
Intra-cluster
(Heartbeat) LAN
Embedded NIC with crossover cable, or, configure as a VLAN through an
Ethernet switch.
See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power
supply (UPS) using any power conditioner or UPS.
Redundant power
distribution units (PDU’s) are strongly recommended.
System software:
Navigator version
L.20.00 or later
Operating System
Service Pack
Microsoft Windows
2000 Advanced Server
SP1 or later
SPU
Model
HP NetServer LP2000r
Clock speed
1 GHz
No. of CPUs
2
BIOS version
4.06.16 or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind
the server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, PCI-1, PCI-2, PCI-3, Embedded SCSI
Microsoft
and HP
Certified
Configuration
P1 – Local storage (NetRAID-1M)
P2 – Shared Storage FC HBA (D8602B)
Booted from NetRAID-1M
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si, NetRAID-3Si, NetRAID-1M,
or NetRAID-2M
For SPOFless, recommend NetRAID-xM with internal drives in RAID-
5, or another fault-tolerant RAID level.
Driver
For embedded SCSI, use SYM_U3.SYS, version 5.07.00 or later.
For NetRAID-xSi, use MRAID35X.SYS, version 2.66 or later.
For NetRAID-xM, use MRAID2K.SYS version 5.20 (Navigator L.20.00
or later)
Cabinets (Physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives
Must be HP (hot swap or fixed).
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI Ids
Any
Shared
HP Rack Storage/12FC
Required
- D5991A
Host Bus Adapter
Model
HP Fibre Channel Host Bus Adapter
- HP D8602B
No. of controllers
1
Driver
HP D8602B
- AFCW2K.SYS 3.0.3245.1