HP LH4r hp netserver lp 2000r netraid-2m config guide — for Micro - Page 2

Local Storage, System software, Power distribution, Controller

Page 2 highlights

lp2000rnt2m Server Configuration Parameter Number of power supplies I/O slots Default boot order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack Power distribution Layout Specification One standard, two required for redundancy Note that in configurations with more than one NetRAID controller, fully populated PCI or hard drive slots, the second power supply is required, and not redundant. Added cards may be installed in any appropriate slot, considering the server default boot order provided below. IDE CD-ROM, FDD, PCI slot 1, PCI slot 2, PCI slot 3, embedded SCSI Embedded SCSI, or NetRAID-1M For embedded SCSI, sym_u3.sys, version 5.05.00, or later For NetRAID-1M, mraidnt.sys, version 4.05, or later (all drivers obtained from Navigator CD-ROM, version L.20.00, or later) Server internal drive bays, or HP external drive cabinet (e.g., HP Rack Storage/12) Must be HP Any HP cables that meet SCSI specifications, and any SCSI bus speed Any Version M.04.00, or later Microsoft Window NTâ Server 4.0, Enterprise Edition SP5 or SP6a and Microsoftâ hotfix Q316743. Please refer to the Microsoftâ product support article at: http://support.microsoft.com/default.aspx?scid=KB;ENUS;q316743&ID=KB;EN-US;q316743 Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Shared Storage Configuration Parameter Specification Controller Model Number of controllers HP NetRAID-2M Controller, Model P3411A, or P3475A One BIOS Disabled Firmware Version H.01.08 (firmware obtained from Navigator CD-ROM, version M.03.00, or later) Driver Mraidnt.sys, version 4.05 (driver obtained from Navigator CD-ROM, version L.20.00, or later) NetRAID Assistant Version B.01.04, or later (software obtained from Navigator CD-ROM, version L.20.00, or later) SCSI ID 6, 7 Channels 0, 1 RAID levels 1, 5, 10, 50 10/21/02 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lp2000rnt2m
Server Configuration
Parameter
Specification
Number of power
supplies
One standard, two required for redundancy
Note that in configurations with more than one NetRAID controller, fully
populated PCI or hard drive slots, the second power supply is required, and not
redundant.
I/O slots
Added cards may be installed in any appropriate slot, considering the server
default boot order provided below.
Default boot order
IDE CD-ROM, FDD, PCI slot 1, PCI slot 2, PCI slot 3, embedded SCSI
Local Storage
Controller
Embedded SCSI, or NetRAID-1M
Driver
For embedded SCSI, sym_u3.sys, version 5.05.00, or later
For NetRAID-1M, mraidnt.sys, version 4.05, or later
(all drivers obtained from Navigator CD-ROM, version L.20.00, or later)
Physical drive location
Server internal drive bays, or HP external drive cabinet
(e.g., HP Rack Storage/12)
Disk drives
Must be HP
SCSI bus
Any HP cables that meet SCSI specifications, and any SCSI bus speed
SCSI IDs
Any
System software
Navigator CD-ROM
Version M.04.00, or later
Operating system
Service pack
Microsoft Window NT
±
Server 4.0, Enterprise Edition
SP5 or
SP6a and Microsoft
±
hotfix Q316743.
Please refer to the Microsoft
±
product support article at:
US;q316743&ID=KB;EN-US;q316743
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 6.
Shared Storage Configuration
Parameter
Specification
Controller
Model
HP NetRAID-2M Controller, Model P3411A, or P3475A
Number of controllers
One
BIOS
Disabled
Firmware
Version H.01.08
(firmware obtained from Navigator CD-ROM, version M.03.00, or later)
Driver
Mraidnt.sys, version 4.05
(driver obtained from Navigator CD-ROM, version L.20.00, or later)
NetRAID Assistant
Version B.01.04, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
SCSI ID
6, 7
Channels
0, 1
RAID levels
1, 5, 10, 50
10/21/02
2