HP LH4r hp netserver lp 2000r netraid-2m config guide — for Micro - Page 3
Enclosure, Cables, Power distribution, Server, Network
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 3 highlights
lp2000rnt2m Shared Storage Configuration Parameter Specification Logical disks One per RAID array Eight, maximum, per cluster Configuration options Cluster mode on Cache write policy to Write thru Enclosure Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. Number of cabinets Model One or two Rack Storage/12 D5989C, containing two D6025C SCSI controller cards Status SCSI ID 5 (fixed) Disk SCSI IDs 0-3, 8-15 (fixed) Cables SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Power distribution Layout Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoftâ and HP Certified Server Configuration Parameter Specification Server I/O card slot Network interfaces Boot device PCI slot 2, NetRAID-2M shared storage controller Embedded NICs for both intra-cluster (heartbeat) and client LANs Embedded SCSI Intra-Cluster (Heartbeat) LAN Configuration Parameter Specification Network Connection HP D5954A crossover cable, or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. NIC Quantity Model One Embedded NIC - LAN A or any model that is on both the HP Tested Products List and the Microsoftâ Hardware Compatibility List. 10/21/02 3