HP LH4r hp netserver lp 2000r netraid-2m config guide — for Micro - Page 3

Enclosure, Cables, Power distribution, Server, Network

Page 3 highlights

lp2000rnt2m Shared Storage Configuration Parameter Specification Logical disks One per RAID array Eight, maximum, per cluster Configuration options Cluster mode on Cache write policy to Write thru Enclosure Disk drives Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in an array, on a SCSI channel, or in a cluster. Number of cabinets Model One or two Rack Storage/12 D5989C, containing two D6025C SCSI controller cards Status SCSI ID 5 (fixed) Disk SCSI IDs 0-3, 8-15 (fixed) Cables SCSI Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Power distribution Layout Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoftâ and HP Certified Server Configuration Parameter Specification Server I/O card slot Network interfaces Boot device PCI slot 2, NetRAID-2M shared storage controller Embedded NICs for both intra-cluster (heartbeat) and client LANs Embedded SCSI Intra-Cluster (Heartbeat) LAN Configuration Parameter Specification Network Connection HP D5954A crossover cable, or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. NIC Quantity Model One Embedded NIC - LAN A or any model that is on both the HP Tested Products List and the Microsoftâ Hardware Compatibility List. 10/21/02 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lp2000rnt2m
Shared Storage Configuration
Parameter
Specification
Logical disks
One per RAID array
Eight, maximum, per cluster
Configuration options
Cluster mode on
Cache write policy to Write thru
Enclosure
Disk drives
Any HP drive supported by storage enclosure.
Any combination of HP disk
models is allowed in an array, on a SCSI channel, or in a cluster.
Number of cabinets
One or two
Model
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0–3, 8–15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page 5.
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page 6.
Microsoft
±
and HP Certified Server Configuration
Parameter
Specification
Server
I/O card slot
PCI slot 2, NetRAID-2M shared storage controller
Network interfaces
Embedded NICs for both intra-cluster (heartbeat) and client LANs
Boot device
Embedded SCSI
Intra-Cluster (Heartbeat) LAN Configuration
Parameter
Specification
Network
Connection
HP D5954A crossover cable, or equivalent.
The intra-cluster LAN may only be used for cluster node communication.
It may
not be used for client communication.
NIC
Quantity
One
Model
Embedded NIC – LAN A
or any model that is on both the HP Tested Products List and the Microsoft
±
Hardware Compatibility List.
10/21/02