HP NetServer LPr with NetRAID-3Si (HP Rack Storage/12 or /8) Cluster Configuration Guide 1 February 2001 (see Versions at the end of this document) Introduction This document defines the supported HP NetServer LPr configurations with HP Rack Storage/12 and Microsoft Cluster Server. These - HP LH4r | HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 2
.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. HP only Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID - HP LH4r | HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 3
HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP LANs LAN connection Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent. The intra-cluster LAN - HP LH4r | HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 4
. Vendor supported driver. NOTE If the NIC used is the same as the Intra-cluster LAN, then the Client LAN must use the same driver as the Intracluster LAN. 1 Shared Storage Cabling This part of the guide defines an allowable cabling configuration for clusters using the HP NetServer LPr and HP Rack - HP LH4r | HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 5
Adapter is installed in server PCI slot P3. A NetRAID-xSi may also be installed for connecting local storage drives. 3. Cables between the servers and shared storage cabinets must be HP LVD SCSI (offset) of any length up to 10 meters. See "Cables" in Rack Storage/12 of the guide for a list of cables - HP LH4r | HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 6
Power Cabling for Cluster Server with Rack Storage/12 6 - HP LH4r | HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 7
intro. Added ultra3 drives. Changed boot definition. Added boot order and driver info. Added support for 800 MHz CPU. Added support for NetRAID-1Si as a cabling drawings for clarity, and added the 36.4 GB hard drive to the Rack Storage/12. Added 500 and 550 MHz CPUs. Note that the BIOS version,
1
HP NetServer LPr
with
NetRAID-3Si (HP Rack Storage/12 or /8)
Cluster Configuration Guide
1 February 2001
(see
Versions
at the end of this document)
Introduction
This document defines the supported HP NetServer LPr configurations with HP Rack Storage/12 and
Microsoft Cluster Server.
These configurations minimize single points of failure (SPOF) and provide
extended availability.
The specific configuration certified and supported by both Hewlett-Packard and
Microsoft is defined, as are other guidelines to assist you in configuring your clustered NetServers.
This
guide is prescriptive; it describes the configurations supported by HP.
Any deviance to these
configurations can result in an inoperative cluster or an operating cluster with degraded performance,
hidden SPOFs, etc., and therefore will not be supported by HP.
What's Defined in the Cluster
Cluster
SPUs
Local and Shared Storage
Intra-cluster and Client LANs
Shared Storage Cabling
Cluster
Type of SPUs
HP NetServer LPr.
Each node must be the same model SPU, but may have
different sizes of main memory, cache, and different CPU clock speeds.
Installation
Racked
Number of nodes
2
Shared Storage
HP Rack Storage/12 with HP NetRAID-3Si controller and HP disks.
See
Shared Storage
below.
LANs:
Client
Any NIC that is HP and Microsoft approved.
See
Client LAN
below.
Intra-cluster/Heartbeat
HP D5013A/B with crossover cable. See
Intra-cluster LAN
below.
Power source
Direct from power mains, power conditioner or uninterruptible power supply
(UPS) using any power conditioner or UPS.
Redundant power distribution
units (PDU’s) are strongly recommended.
System software:
Navigator version
(or later)
L.14.00 - 400, 450 MHz with Rack Storage/12 Model D5989A
L.16.00 - 400, 450, 500, 550 MHz with Rack Storage/12 Model D5989B
L.17.05 - 600, 650, 700 MHz with Rack Storage/12 Model D5989B
L.18.03 – 800 MHz with Rack Storage/12 Model D5989B
M.01.00 – 850 MHz with Rack Storage/12 Model D5989C
Operating System