HP LH4r HP Netserver LPr NetRAID-3Si Cluster Config Guide for Windows NT4.0 C - Page 3

D5989B or C plus two D6025B's or two D6025C's for each Rack

Page 3 highlights

Configuration options: Cluster mode on Cache write-policy to Write thru Set any other options as you prefer Cabinet RAID arrays A RAID array (logical disk) must be composed of all the same disk model (i.e., part number and suffix). Different size or speed disks are not allowed in the same RAID array. Any combination of disk models is allowed on a SCSI channel and in a cluster. Number of cabinets Rack Storage/12: Model Status SCSI ID Disk SCSI IDs Disk drives: 1 - 3 D5989B or C plus two D6025B's or two D6025C's for each Rack Storage/12 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A HP 18.2 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D7031A HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A HP 18.2 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D7174A HP 18.2 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D7175A HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A Cables Any 2 HP LVD SCSI cables from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A LANs LAN connection Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent. The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. 3 Client LAN Any LAN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

3
Configuration
options:
Cluster mode on
Cache write-policy to Write thru
Set any other options as you prefer
Cabinet
RAID arrays
A RAID array (logical disk) must be composed of all the same disk model
(i.e., part number and suffix).
Different size or speed disks are not
allowed in the same RAID array.
Any combination of disk models is
allowed on a SCSI channel and in a cluster.
Number of cabinets
1 – 3
Rack Storage/12:
Model
D5989B or C plus two D6025B’s or two D6025C’s for each Rack
Storage/12
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0 – 3,
8 – 15 (fixed)
Disk drives:
Any HP drive supported by storage enclosure including:
HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A
HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A
HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A
HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A
HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A
HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A
HP 18.2 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D7031A
HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A
HP 18.2 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D7174A
HP 18.2 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D7175A
HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A
HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A
Cables
Any 2 HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent.
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable.
It may not be used for client
communication.