Storage

Page 2 highlights

Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM Local storage I/O slots Default Boot Order M/S Certified Configuration Storage SP6a or later HP NetServer LPr 400, 450, 500, 550, 600, 650, 700, 800, 850 MHz. 2 4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A) 4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B) 4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B) 4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B) 4.06.32 PR or later (800 MHz with Rack Storage/12 D5989B) 4.06.33 PR or later (850 MHz with Rack Storage/12 D5989C) Any size 128 MB minimum. Must be HP. See Local Storage below. Added cards may be installed in any appropriate slot, keeping in mind the server's default boot order as listed below: IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4 P1 - Local storage (NetRAID-1Si) P2 - Client LAN P3 - Shared storage (NetRAID-3Si) P4 -- Intra-cluster (Heartbeat) LAN Booted from NetRAID-1Si Local Controller Driver Cabinets (physical drive location) Disk drives (hot swap or fixed) SCSI bus SCSI IDs May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si. For embedded SCSI, use sym_hi.version 4.12 or later. For embedded DAC and NetRAID-xSi, use mraidnt.sys version 2.24. SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/12), any number. HP only Any HP cables that meet SCSI specifications and any SCSI bus speed. Any Shared Controller Model No. of controllers Firmware BIOS Driver NetRAID Assistant SCSI ID Channels RAID level Logical disks HP NetRAID-3Si Adapter D5955A 1 W.01.30 B.02.02 Mraidnt.sys 2.24 A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array 8 maximum per NetRAID adapter 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

2
Service pack
SP6a or later
SPU
Model
HP NetServer LPr
Clock speed
400, 450, 500, 550, 600, 650, 700, 800, 850 MHz.
No. of CPUs
2
BIOS version
4.06.09 PR or later (400, 450 MHz with Rack Storage/12 D5989A)
4.06.14.PR or later (400, 450 MHz with Rack Storage/12 D5989B)
4.06.14.PR or later (500, 550 MHz with Rack Storage/12 D5989B)
4.06.29.PR or later (600, 650, 700 MHz with Rack Storage/12 D5989B)
4.06.32 PR or later (800 MHz with Rack Storage/12 D5989B)
4.06.33 PR or later (850 MHz with Rack Storage/12 D5989C)
CPU cache
Any size
RAM
128 MB minimum.
Must be HP.
Local storage
See
Local Storage
below.
I/O slots
Added cards may be installed in any appropriate slot, keeping in mind the
server's default boot order as listed below:
Default Boot Order
IDE CD-ROM, FDD, Embedded SCSI, PCI-3, PCI-2, PCI-1, PCI-4
M/S Certified
Configuration
P1 – Local storage (NetRAID-1Si)
P2 - Client LAN
P3 – Shared storage (NetRAID-3Si)
P4 -- Intra-cluster (Heartbeat) LAN
Booted from NetRAID-1Si
Storage
Local
Controller
May use embedded SCSI, NetRAID-1Si, or NetRAID-3Si.
Driver
For embedded SCSI, use sym_hi.version 4.12 or later.
For embedded
DAC and NetRAID-xSi, use mraidnt.sys version 2.24.
Cabinets (physical drive
location)
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/12), any number.
Disk drives (hot swap
or fixed)
HP only
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed.
SCSI IDs
Any
Shared
Controller
Model
HP NetRAID-3Si Adapter D5955A
No. of controllers
1
Firmware
W.01.30
BIOS
B.02.02
Driver
Mraidnt.sys 2.24
NetRAID Assistant
A.01.15 or later
SCSI ID
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array
8 maximum per NetRAID adapter