HP LH4r hp netserver lt 6000r netraid-4m config guide — for Micro - Page 3

Enclosure, Cables, Power distribution

Page 3 highlights

lt6000rnt4m Shared Storage Configuration Parameter NetRAID-4M FAST SCSI ID Channels RAID levels Containers Configuration options Enclosure Disk drives Number of cabinets Model Status SCSI ID Disk SCSI IDs Cables SCSI Power distribution Layout Specification Ultra2 models - Version 2.4-0, or later (software obtained from Navigator CD-ROM, version L.20.00, or later) Ultra3 models - Version 2.4-1, displayed in FAST as version 4605, or later (software obtained from Navigator CD-ROM, version M.04.00, or later) 6, 7 0, 1, 2, 3 All fault-tolerant RAID types supported by controller: 1, 5, 10 (stripe set of mirror sets RAID 0/1), 50 (stripe set of RAID-5 sets), volume set of mirror sets, volume set of RAID-5 sets Single-level or multi-level Must be fault-tolerant Eight, maximum, per cluster Write cache disabled Clustering enabled Domain validation enabled Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in a diskset, on a SCSI channel, or in a cluster. Up to eight Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or Rack Storage/12 D5989C, containing two D6025C SCSI controller cards 5 (fixed) 0-3, 8-15 (fixed) Any two HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A See SCSI cabling diagram on page 5. Redundant power distribution units (PDUs) are recommended. See power cabling diagram on page 6. Microsoft® and HP Certified Server Configuration Parameter I/O card slot Network interfaces Boot device Specification PCI slot 5, NetRAID-4M shared storage controller PCI slot 2, model D5013B, client LAN Embedded DAC 1/28/02 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

lt6000rnt4m
1/28/02
3
Shared Storage Configuration
Parameter
Specification
NetRAID-4M FAST
Ultra2 models —
Version 2.4-0, or later
(software obtained from Navigator CD-ROM, version L.20.00, or later)
Ultra3 models —
Version 2.4-1, displayed in FAST as version 4605, or later
(software obtained from Navigator CD-ROM, version M.04.00, or later)
SCSI ID
6, 7
Channels
0, 1, 2, 3
RAID levels
All fault-tolerant RAID types supported by controller:
1, 5, 10 (stripe set of
mirror sets RAID 0/1), 50 (stripe set of RAID-5 sets), volume set of mirror sets,
volume set of RAID-5 sets
Containers
Single-level or multi-level
Must be fault-tolerant
Eight, maximum, per cluster
Configuration options
Write cache disabled
Clustering enabled
Domain validation enabled
Enclosure
Disk drives
Any HP drive supported by storage enclosure.
Any combination of HP disk
models is allowed in a diskset, on a SCSI channel, or in a cluster.
Number of cabinets
Up to eight
Model
Rack Storage/12 D5989B, containing two D6025B SCSI controller cards, or
Rack Storage/12 D5989C, containing two D6025C SCSI controller cards
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0–3, 8–15 (fixed)
Cables
SCSI
Any two HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
See
SCSI cabling diagram
on page
5
.
Power distribution
Layout
Redundant power distribution units (PDUs) are recommended.
See
power cabling
diagram
on page
6
.
Microsoft
°
and HP Certified Server Configuration
Parameter
Specification
I/O card slot
PCI slot 5, NetRAID-4M shared storage controller
Network interfaces
PCI slot 2, model D5013B, client LAN
Boot device
Embedded DAC