HP LH4r HP Netserver LXr 8000 Surestore E Config Guide for Windows NT4.0 Clus - Page 2

Storage

Page 2 highlights

Service pack SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: Storage SP4 or later HP NetServer LXr 8000 400 and 450 MHz 2 - 4 ASPN1.86L.0003.P03.981041252 or later Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P3, P4, or P7 - Shared storage controller P1 - Local storage P5 - Intra-cluster (Heartbeat) LAN P6 - Client LAN All others - Any other plug-in cards. Local Physical drive location Disk drives Controller SCSI bus Shared Host Bus Adapter Model No. of HBA Driver SPU I/O slot SCSI ID Disk Array Controller Model No. of controllers Firmware RAID level (internal) Logical disks Hot spare SCSI ID Disk Array Storage Model SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8 or /12) Must be HP May use embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any controller listed on the HP Tested Products List. May not use embedded RAID, NetRAID-1, NetRAID-3, or NetRAID1Si. Any HP cables that meet SCSI specifications and any SCSI bus speed HP A5252B Wide Differential SCSI Adapter 1 - 3 per NetServer Adaptec AHA-294X/AHA-394X/AIC-78XX SCSI Controller driver in NT 4.0 SP4 or later P3 (1st HBA), P4 (2nd HBA), P7 (3rd HBA) 7 HP A3706A 96MB Controller with SureStore E 12H 2 per SureStore E 12H HP54 or later (SureStore E 12H NT 3.0 release) 1/0 and 5 Logical units within each array must be numbered from 0 - 7 Active Hot Spare 0 - 6 or 8 - 15 HP A3700AB SureStore E 12H Disk Array 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

2
Service pack
SP4 or later
SPU
Model
HP NetServer LXr 8000
Clock speed
400 and 450 MHz
No. of CPUs
2 – 4
BIOS version
ASPN1.86L.0003.P03.981041252 or later
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
I/O slots:
P3, P4, or P7 – Shared storage controller
P1 – Local storage
P5 – Intra-cluster (Heartbeat) LAN
P6 – Client LAN
All others – Any other plug-in cards.
Storage
Local
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8 or /12)
Disk drives
Must be HP
Controller
May use
embedded SCSI or NetRAID-3Si in PCI slot P1 otherwise any
controller listed on the HP Tested Products List.
May not use
embedded RAID, NetRAID-1, NetRAID-3, or NetRAID-
1Si.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Host Bus Adapter
Model
HP A5252B Wide Differential SCSI Adapter
No. of HBA
1 – 3 per NetServer
Driver
Adaptec AHA-294X/AHA-394X/AIC-78XX SCSI Controller driver in
NT 4.0 SP4 or later
SPU I/O slot
P3 (1
st
HBA), P4 (2
nd
HBA), P7 (3
rd
HBA)
SCSI ID
7
Disk Array Controller
Model
HP A3706A 96MB Controller with SureStore E 12H
No. of controllers
2 per SureStore E 12H
Firmware
HP54 or later (SureStore E 12H NT 3.0 release)
RAID level (internal)
1/0 and 5
Logical disks
Logical units within each array must be numbered from 0 – 7
Hot spare
Active Hot Spare
SCSI ID
0 – 6 or 8 – 15
Disk Array Storage
Model
HP A3700AB SureStore E 12H Disk Array