HP LH4r HP Netserver LXr 8000 Surestore E Config Guide for Windows NT4.0 Clus - Page 3

Shared Storage Cabling

Page 3 highlights

No. of cabinets Disk modules: Power supply SureStore E Manager Cabling Terminator 1 - 6; maximum 2 SureStore E 12Hs per SCSI bus HP A3702A 4.2 GB Disk Module HP A3703A 9.1 GB Disk Module HP A3710A 18.2 GB Disk Module 3 3.0 or later HP C2981A 0.5 meter Ultra-flexible SCSI Cable HP C2911A 0.9 meter 68-pin HD Male to 68-pin HD Male Cable HP C2924A 2.5 meter 68-pin HD Male to 68-pin HD Male Cable HP C2925A 10 meter 68-pin HD Male to 68-pin HD Male Cable (Maximum 25 meters per SCSI bus) HP C2905A Wide Differential SCSI Terminator LANs LAN connection NIC: Model Driver No. of NICs SPU I\O slot Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. Client LAN Any LAN HP D5013A (10/100TX PCI) 3.27.00.0001 or later (Do not enable FEC Features.) 1 P5 Any that is on both the HP Tested Products List and the Microsoft Hardware Compatibility List. Any driver NOTE: If the NIC used is the same as the Intra-cluster LAN, then the Client LAN must use the same driver as the Intracluster LAN. 1 minimum P6 Shared Storage Cabling This part of the guide defines the allowable cabling configurations for Change name here? NetServer clusters using the HP SureStore E 12H Disk Array. Only these cabling configurations and cables are supported. These diagrams show single and daisy-chained configurations. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

3
No. of cabinets
1 – 6; maximum 2 SureStore E 12Hs per SCSI bus
Disk modules:
HP A3702A 4.2 GB Disk Module
HP A3703A 9.1 GB Disk Module
HP A3710A 18.2 GB Disk Module
Power supply
3
SureStore E Manager
3.0 or later
Cabling
HP C2981A 0.5 meter Ultra-flexible SCSI Cable
HP C2911A 0.9 meter 68-pin HD Male to 68-pin HD Male Cable
HP C2924A 2.5 meter 68-pin HD Male to 68-pin HD Male Cable
HP C2925A 10 meter 68-pin HD Male to 68-pin HD Male Cable
(Maximum 25 meters per SCSI bus)
Terminator
HP C2905A Wide Differential SCSI Terminator
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent
Any LAN
The intra-cluster LAN may only be used for
cluster node communication via a crossover
cable.
It may not be used for client
communication.
NIC:
Model
HP D5013A
(10/100TX PCI)
Any that is on both the HP
Tested Products List and the
Microsoft Hardware
Compatibility List.
Driver
3.27.00.0001 or later (Do not enable FEC
Features.)
Any driver
NOTE:
If the NIC used is the
same as the Intra-cluster LAN,
then the Client LAN must use
the same driver as the Intra-
cluster LAN.
No. of NICs
1
1 minimum
SPU I\O slot
P5
P6
Shared Storage Cabling
This part of the guide defines the allowable cabling configurations for Change name here? NetServer
clusters using the HP SureStore E 12H Disk Array.
Only these cabling configurations and cables are
supported.
These diagrams show single and daisy-chained configurations.