HP MSA2324i HP StorageWorks 2000 G2 Modular Smart Array reference guide (50091 - Page 95
SC has not received communication from the, than 15 minutes, event 153 is logged. If
View all HP MSA2324i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 116 Critical After a recovery, the partner controller was killed while mirroring write-back data to the current controller. The current controller restarted to avoid losing the data in the partner controller's cache, but if the other controller does not restart successfully, the data will be lost. To determine if data might have been lost, check whether this event was immediately followed by restart event 56, closely followed by failover event 71 (specifying p1=1). 118 Informational Cache parameters have been changed for the specified vdisk. 127 Warning The controller has detected an invalid disk dual-port connection. This connection does not have the benefit of fault tolerance. Failure of the disk port would cause loss of access to the disk. The single disk port should be connected to one controller only. 136 Warning Errors detected on the specified disk channel Determine the source of the errors on the have caused the storage system to mark the specified disk channel and replace the faulty channel as degraded. hardware. When the problem is fixed, event 189 is logged. 139 Informational The MC has powered up or restarted. 140 Informational The MC is about to restart. 141 Informational The IP address has been changed in the MC. 152 Informational The MC has not sent a command to the SC If this occurs repeatedly and user interfaces or warning for an interval that exceeds the MC are not working normally, a hardware failure communication timeout, and may have is indicated. Replace the controller module failed. This is sometimes referred to as a that is logging this event. "LAN not talking" error. This event is logged as informational when the SC has not received communication from the MC for 160 seconds. If communication is restored in less than 15 minutes, event 153 is logged. If the SC has not received communication from the MC for 15 minutes, this event is logged as a warning, the SC restarts the MC, and event 156 is logged. 153 Informational The MC has re-established communication with the SC. 154 Informational New software has been loaded on the MC. 155 Informational New loader software has been loaded on the MC. 156 Informational The MC has been restarted from the SC. 157 Critical A failure occurred when trying to write to the Replace the controller module. SC flash chip. 158 Informational A correctable ECC error occurred in the CPU memory. 160 Warning The EMP enclosures are not configured Check that EMP enclosures are configured correctly. All enclosure EMPs on that channel correctly and issue a rescan. are disabled. HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 95