HP Model 712/100 hp DDS-3 tape drive user's guide (a1658-90702) - Page 13
DDS-3 Drive Environmental Requirements - 80
View all HP Model 712/100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Introduction DDS-3 Drive Environmental Requirements The DDS-3 drive has the following environmental requirements: • Ambient Temperature Operating Non-Operating 5_ C to 40_ C (41_ F to 104_ F) -40_ C to 70_ C (-40_ F to 158_ F) • Humidity Operating Non-Operating 20% to 80%RH (non-condensing) 5% to 95%RH Maximum wet bulb temperature = 26_ C • Vibration Operating (3 axes for drives, 1 axis for autoloaders) Swept Sine Random 0.3 g peak, 5-500 Hz @ 1 octave/min 5-350 Hz @ 0.00053 g2/Hz HP C1534A/ 350-500 Hz @ -6 dB/octave 36A/53A Random 500 Hz @ 0.000271 g2/Hz (≈0.5 g rms) 5-350 Hz @ 0.0002 g2/Hz HP C1533A/ HP C1537A 350-500 Hz @ -6 dB/octave 500 Hz @ 0.0001 g2/Hz (≈0.3 g rms) Non-Operating Swept Sine Random 0.75 g peak, 5-500 Hz @ 1 octave/min 5-100 Hz @ 0.020 g2/Hz 100-137 Hz @ -6 dB/octave 137-350 Hz @ 0.0107 g2/Hz 350-500 Hz @ -6 dB/octave 500 Hz @ 0.0052 g2/Hz (≈2.41 g rms) 1-3