system. Turn FASTBOOT OFF at the BOOT_ADMIN prompt, set FASTSIZE
View all HP Model 715/100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
2. Determine the SIMM pair that contains the System Responder Address (as shown using the PIM_INFO command) within its range. Evaluate the SIMM pairs, as follows: NOTICE: Addressing starts at Pair 3, not Pair 0. A. If the System Responder Address (as shown using the PIM_INFO COMMAND) is between 0x00000000 and 0x03FFFFFF: Error in Pair 3 B. If the System Responder Address (as shown using the PIM_INFO COMMAND) is between 0x04000000 and 0x05FFFFFF: Error in Pair 2 C. If the System Responder Address is between 0x06000000 and 0x09FFFFFF Error in Pair 1 D. If the System Responder Address is between 0x0A000000 and 0x0AFFFFFF Error in Pair 0 E. If Responder Address is between 0x0B00000 and 0x0FFFFFFF Address Space Not Filled; (Probable) Motherboard Failure F. If Responder Address is between 0x10000000 and 0xEFFFFFFF Invalid Address Space; (Probable) Motherboard Failure 3. Without the actual failed bit number, the failed pair number is as close a deter- mination as possible. To try to locate the faulty (individual) SIMM, reboot the system. Turn FASTBOOT OFF at the BOOT_ADMIN prompt, set FASTSIZE to ALL OF MEMORY (0F), and power cycle again. If the (destructive) memory selftest locates the faulty SIMM, the corresponding Chassis Code is shown on the LEDs replace the faulty SIMM, otherwise, replace the SIMM pair identified in this procedure. Return the system state (e.g., FASTBOOT) to original condition. 4-28 Troubleshooting