HP NetServer LXr Pro8 HP Netserver LXr 8500 NetRAID-4M Config Guide for Windo - Page 3

Clustering Enabled, Intra-cluster Heartbeat LAN, Client LAN

Page 3 highlights

Driver NetRAID-4M FAST SCSI ID Channels RAID levels Containers Configuration options: Cabinet Disk drives: No. of cabinets Model Status SCSI ID Disk SCSI Ids Hpn.sys version 2.4.0.4581 2.4-0 or later 6, 7 0, 1, 2, 3 All fault tolerant RAID types supported by controller: 1, 5, 10 (Stripe set of mirror sets RAID 0/1), 50 (Stripe set of RAID-5 sets), Volume set of mirror sets, Volume set of RAID-5 sets Single-level or multi-level Must be fault-tolerant 8 maximum per cluster Write Cache Disabled Clustering Enabled Domain Validation Enabled Any HP drive supported by storage enclosure. Any combination of HP disk models is allowed in a diskset, on a SCSI channel, or in a cluster. 1 - 8 Rack Storage/12 D5989B or C plus two D6205B or two D6025C SCSI controllers for each Rack Storage/12 5 (fixed) 0 - 3, 8 - 15 (fixed) Cables LANs LAN connection NIC: Model Driver No. of NICs Any 2 HP LVD SCSI offset cables per RS/12 from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or equivalent. The intra-cluster LAN may only be used for cluster node communication. It may not be used for client communication. Client LAN Any LAN HP D5013B (10/100TX PCI) Hptxnt5.sys 4.02.27 (Navigator L.20.00) or later 1 Any that is on both the HP Tested Products List and the Microsoft® Hardware Compatibility List. Vendor supported driver NOTE If the NIC used is the same as the Intra-cluster LAN (HP D5013B), then the Client LAN must use the same driver as the Intra-cluster LAN. 1 minimum 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

3
Driver
Hpn.sys version 2.4.0.4581
NetRAID-4M FAST
2.4-0 or later
SCSI ID
6, 7
Channels
0, 1, 2, 3
RAID levels
All fault tolerant RAID types supported by controller: 1, 5, 10 (Stripe set
of mirror sets RAID 0/1), 50 (Stripe set of RAID-5 sets), Volume set of
mirror sets,
Volume set of RAID-5 sets
Containers
Single-level or multi-level
Must be fault-tolerant
8 maximum per cluster
Configuration
options:
Write Cache Disabled
Clustering Enabled
Domain Validation Enabled
Cabinet
Disk drives:
Any HP drive supported by storage enclosure.
Any combination of HP
disk models is allowed in a diskset, on a SCSI channel, or in a cluster.
No. of cabinets
1 – 8
Model
Rack Storage/12 D5989B or C plus two D6205B or two D6025C SCSI
controllers for each Rack Storage/12
Status SCSI ID
5 (fixed)
Disk SCSI Ids
0 – 3,
8 – 15 (fixed)
Cables
Any 2 HP LVD SCSI offset cables per RS/12 from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or
equivalent.
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication.
It may not be used
for client communication.
NIC:
Model
HP D5013B
(10/100TX PCI)
Any that is on both the HP Tested
Products List and the Microsoft
Hardware Compatibility List.
Driver
Hptxnt5.sys 4.02.27 (Navigator
L.20.00) or later
Vendor supported driver
NOTE
If the NIC used is the
same as the Intra-cluster LAN
(HP D5013B), then the Client
LAN must use the same driver as
the Intra-cluster LAN.
No. of NICs
1
1 minimum