HP NetServer LXr Pro8 HP Netserver LPr with XP256 Cluster Config Guide for Wi - Page 2
Storage
View all HP NetServer LXr Pro8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: HP NetServer LPr. 400, 450, 500, or 550 MHz 2 - 4 4.06.14PR Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P1 - P4 Shared storage controller P2 - NetRAID-3Si local storage P3 - Client LAN P4 - Intra-cluster (Heartbeat) LAN Storage Local Physical drive location Disk drives Controller SCSI bus Shared Host Bus Adapters Model Bus Protocol No. of HBAs/Server Firmware BIOS Driver SPU I/O slot SCSI ID Registry Changes SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8 only. Must be HP Embedded SCSI controller to internal disks or any external cabinet. NetRAID (D4943A) with firmware A.04.00 or later to internal disks or Rack Storage/8 only. NetRAID-1 (D4992A) with firmware A.04.00 or later to internal disks or Rack Storage/8 only. Any HP cables that meet SCSI specifications and any SCSI bus speed Fibre Channel HBA D8602A FC Public NL 1 NA NA 2.00 or later Available at http://www.semiconductor.agilent. com/io/hhba5101.html P3 - P4 NA I/O Timeout= 60 Seconds SCSI HBA A5252B or Adaptec AHA2944UW Ultra Wide or Fast Wide 1 N/A 2.11 (B.01.08) SP5 bundle version P3-P4 7 or 6 I/O Timeout=60 seconds Queue Tag Count=8 (MAXTAGS=8) 2