Storage

Page 2 highlights

SPU Model Clock speed No. of CPUs BIOS version CPU cache RAM No. of power supplies Local storage I/O slots: HP NetServer LPr. 400, 450, 500, or 550 MHz 2 - 4 4.06.14PR Any size 256 MB minimum. Must be HP. 3 See Local Storage below. P1 - P4 Shared storage controller P2 - NetRAID-3Si local storage P3 - Client LAN P4 - Intra-cluster (Heartbeat) LAN Storage Local Physical drive location Disk drives Controller SCSI bus Shared Host Bus Adapters Model Bus Protocol No. of HBAs/Server Firmware BIOS Driver SPU I/O slot SCSI ID Registry Changes SPU internal drive bays or HP external drive cabinet (e.g., HP Rack Storage/8 only. Must be HP Embedded SCSI controller to internal disks or any external cabinet. NetRAID (D4943A) with firmware A.04.00 or later to internal disks or Rack Storage/8 only. NetRAID-1 (D4992A) with firmware A.04.00 or later to internal disks or Rack Storage/8 only. Any HP cables that meet SCSI specifications and any SCSI bus speed Fibre Channel HBA D8602A FC Public NL 1 NA NA 2.00 or later Available at http://www.semiconductor.agilent. com/io/hhba5101.html P3 - P4 NA I/O Timeout= 60 Seconds SCSI HBA A5252B or Adaptec AHA2944UW Ultra Wide or Fast Wide 1 N/A 2.11 (B.01.08) SP5 bundle version P3-P4 7 or 6 I/O Timeout=60 seconds Queue Tag Count=8 (MAXTAGS=8) 2

  • 1
  • 2
  • 3
  • 4
  • 5

2
SPU
Model
HP NetServer LPr.
Clock speed
400, 450, 500, or 550 MHz
No. of CPUs
2 – 4
BIOS version
4.06.14PR
CPU cache
Any size
RAM
256 MB minimum.
Must be HP.
No. of power supplies
3
Local storage
See
Local Storage
below.
I/O slots:
P1 – P4 Shared storage controller
P2 – NetRAID-3Si local storage
P3 – Client LAN
P4 – Intra-cluster (Heartbeat) LAN
Storage
Local
Physical drive location
SPU internal drive bays or HP external drive cabinet (e.g., HP Rack
Storage/8 only.
Disk drives
Must be HP
Controller
Embedded SCSI controller to internal disks or any external cabinet.
NetRAID (D4943A) with firmware A.04.00 or later to internal disks or
Rack Storage/8 only.
NetRAID-1 (D4992A) with firmware A.04.00 or later to internal disks or
Rack Storage/8 only.
SCSI bus
Any HP cables that meet SCSI specifications and any SCSI bus speed
Shared
Host Bus Adapters
Fibre Channel HBA
SCSI HBA
Model
D8602A
A5252B or
Adaptec AHA2944UW
Bus Protocol
FC Public NL
Ultra Wide or Fast Wide
No. of HBAs/Server
1
1
Firmware
NA
N/A
BIOS
NA
2.11 (B.01.08)
Driver
2.00 or later
Available at
com/io/hhba5101.html
SP5 bundle version
SPU I/O slot
P3 – P4
P3-P4
SCSI ID
NA
7 or 6
Registry Changes
I/O Timeout= 60 Seconds
I/O Timeout=60 seconds
Queue
Tag Count=8
(MAXTAGS=8)