HP NetServer LXr Pro8 HP Netserver LT6000r NetRAID-3Si Config Guide for Windo - Page 3

Intra-cluster Heartbeat LAN, Client LAN

Page 3 highlights

NetRAID Assistant SCSI Ids Channels RAID level Logical disks Configuration options A.01.15 or later 6, 7 0, 1, 2 1, 5, 10, 50 1 per RAID array 8 maximum per NetRAID-3Si adapter Cluster mode on Cache write policy to Write thru Cabinet RAID arrays Number of cabinets Cabinet type Model Status SCSI ID Disk SCSI IDs Disk drives: Cables LANs LAN connection A RAID (logical disk) must be composed of all the same disk model (i.e., part number and suffix). Different disk drive sizes or speeds are not allowed in the same array. Any combination of disk models is allowed on a SCSI channel. Any combination of disk models is allowed in a cluster. 1-3 HP Rack Storage/12 D5989B plus two D6025B SCSI cards for each cabinet 5 (fixed) 0 - 3, 8 - 15 (fixed) Any HP drive supported by storage enclosure including: HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A HP 18.2 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D7031A HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A HP 18.2 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D7174A HP 18.2 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D7175A HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A Any 2 HP LVD SCSI cables from the following list: 1 meter D7131A 2.5 meter D6020A 5 meter D6982A 10 meter D6983A Intra-cluster (Heartbeat) LAN HP D5954A crossover cable or any equivalent. The intra-cluster LAN may only be used for cluster node communication via a crossover cable. It may not be used for client communication. Client LAN Any LAN 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7

3
NetRAID Assistant
A.01.15 or later
SCSI Ids
6, 7
Channels
0, 1, 2
RAID level
1, 5, 10, 50
Logical disks
1 per RAID array
8 maximum per NetRAID-3Si adapter
Configuration
options
Cluster mode on
Cache write policy to Write thru
Cabinet
RAID arrays
A RAID
(logical disk) must be composed of all the same disk model (i.e.,
part number and suffix). Different disk drive sizes or speeds are not
allowed in the same array. Any combination of disk models is allowed on
a SCSI channel. Any combination of disk models is allowed in a cluster.
Number of cabinets
1-3
Cabinet type
HP Rack Storage/12
Model
D5989B plus two D6025B SCSI cards for each cabinet
Status SCSI ID
5 (fixed)
Disk SCSI IDs
0 – 3,
8 – 15 (fixed)
Disk drives:
Any HP drive supported by storage enclosure including:
HP 9.1 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D6106A
HP 9.1 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1217A
HP 9.1 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D6107A
HP 9.1 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1168A
HP 18.2 GB (7200 rpm) Half Height Ultra2 SCSI Disk Module D6108A
HP 18.2 GB (7200 rpm) Low Profile Ultra3 SCSI Disk Module P1216A
HP 18.2 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D7031A
HP 18.2 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module P1166A
HP 18.2 GB (7200 rpm) Low Profile Ultra2 SCSI Disk Module D7174A
HP 18.2 GB (10k rpm) Low Profile Ultra2 SCSI Disk Module D7175A
HP 36.4 GB (10k rpm) Half Height Ultra2 SCSI Disk Module D8210A
HP 36.4 GB (10k rpm) Low Profile Ultra3 SCSI Disk Module D9419A
Cables
Any 2 HP LVD SCSI cables from the following list:
1 meter D7131A
2.5 meter D6020A
5 meter D6982A
10 meter D6983A
LANs
Intra-cluster (Heartbeat) LAN
Client LAN
LAN connection
HP D5954A crossover cable or any
equivalent.
Any LAN
The intra-cluster LAN may only be
used for cluster node
communication via a crossover
cable.
It may not be used for client