HP P10000 HP 3PAR HP-UX 11i v2, v3 Implementation Guide (QL226-96021, August 2 - Page 15

Run the Support Tools Manager STM utility

Page 15 highlights

# FibrChanl-00 B.11.23.0712 PCI FibreChannel;Supptd HW=A6795A,A5158A FibrChanl-00.FC-TACHYON-TL B.11.23.0712 PCI FibreChannel;Supptd HW=A6795A,A5158A # FibrChanl-01 B.11.23.08.02 FibrChnl;SupptdHW=A6826A,A9782A,A9784A,AB378A,AB379A,AB465A,AD193A,AD194A,AD300A FibrChanl-01.FC-FCD Driver(FCD) # FibrChanl-02 HW=AD299A,AD355A FibrChanl-02.FC-FCLP B.11.23.08.02 HP PCI-X/PCIe FibreChannel B.11.23.0712 PCIe FibreChannel;Supptd B.11.23.0712 PCIe FibreChannel The drivers are installed as part of the operating system install. FibreChanl-00 must be also installed for FibrChanl-01 to function. 2. Verify that the OnlineDiag or Support Tools Bundle software is installed and install the software if it is not present. The OnlineDiag bundle is present in the OS media. # swlist Online* # OnlineDiag Tools Bundle, September 2008 B.11.31.04.05 HPUX 11.31 Support 3. HP recommends that the Server is at a certain firmware version to detect the Fibre Channel Cards. Verify the firmware version using the MP interface on the Integrity or HP 9000 Server. MP:CM> SYSREV FIRMWARE: Core IO Master Event Dict. Slave Event Dict. Cell 0 PDHC Pri SFW Sec SFW Cell 1 PDHC Pri SFW Sec SFW : A.006.012 : 1.009 : A.006.012 : 1.009 : A.003.023 : 22.002 (PA) : 1.025 (IA) : A.003.023 : 22.002 (PA) : 1.025 (IA) Alternately, if the Online Diagnostics have been installed, run the cstm tool to determine the firmware version. a. Run the Support Tools Manager (STM) utility cstm. # /usr/sbin/cstm b. Use the selall and ilcommands to find all the required system information. cstm>selall cstm>il ... Product ID Product Number System Firmware Revision BMC Revision System Serial Number: System Software ID : ia64 hp server rx7620 : not set : 001.025 : v06.12 : not set : 3801066248 Installing the Host OS 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

# FibrChanl-00
B.11.23.0712
PCI FibreChannel;Supptd
HW=A6795A,A5158A
FibrChanl-00.FC-TACHYON-TL
B.11.23.0712
PCI FibreChannel;Supptd
HW=A6795A,A5158A
# FibrChanl-01
B.11.23.08.02
FibrChnl;SupptdHW=A6826A,A9782A,A9784A,AB378A,AB379A,AB465A,AD193A,AD194A,AD300A
FibrChanl-01.FC-FCD
B.11.23.08.02
HP PCI-X/PCIe FibreChannel
Driver(FCD)
# FibrChanl-02
B.11.23.0712
PCIe FibreChannel;Supptd
HW=AD299A,AD355A
FibrChanl-02.FC-FCLP
B.11.23.0712
PCIe FibreChannel
The drivers are installed as part of the operating system install.
FibreChanl-00
must
be also installed for
FibrChanl-01
to function.
2.
Verify that the OnlineDiag or Support Tools Bundle software is installed and install the software
if it is not present. The OnlineDiag bundle is present in the OS media.
# swlist Online*
# OnlineDiag
B.11.31.04.05 HPUX 11.31 Support
Tools Bundle, September 2008
3.
HP recommends that the Server is at a certain firmware version to detect the Fibre Channel
Cards. Verify the firmware version using the MP interface on the Integrity or HP 9000 Server.
MP:CM> SYSREV
FIRMWARE:
Core IO
Master
:
A.006.012
Event Dict.
:
1.009
Slave
:
A.006.012
Event Dict.
:
1.009
Cell 0
PDHC
:
A.003.023
Pri SFW
:
22.002 (PA)
Sec SFW
:
1.025 (IA)
Cell 1
PDHC
:
A.003.023
Pri SFW
:
22.002 (PA)
Sec SFW
:
1.025 (IA)
Alternately, if the Online Diagnostics have been installed, run the
cstm
tool to determine the
firmware version.
a.
Run the Support Tools Manager (STM) utility
cstm
.
# /usr/sbin/cstm
b.
Use the
selall
and
il
commands to find all the required system information.
cstm>selall
cstm>il
...
Product ID
: ia64 hp server rx7620
Product Number
: not set
System Firmware Revision
: 001.025
BMC Revision
: v06.12
System Serial Number:
: not set
System Software ID
: 3801066248
Installing the Host OS