HP Pavilion 9700 HP Pavilion PC's - PCTEL V.90/K56Flex Series AT Command Guide - Page 24

V90K56DOCATC11A, 2800 baud N/A

Page 24 highlights

AT Command Guide 34 V.90 data rate (bit-rate) Set the maximum bit rate for V.90 Range: 0-21 bit rate = 28000 + S34 * 1333bps K56Flex data rate (bit-rate) Set the maximum bit rate for 56K Range: 0-12 bit rate = 32000bps + S34 * 2000bps V.34 data rate (bit-rate) Set the maximum bit rate for V.34 Range : 0-8 (2400 baud) bit rate = ((S34)+1) * 2400bps Default: 21 (33600 bps) 35 V.34 symbol rate (baud-rate) Set the maximum baud rate for V.34 Range: 0-5 0 - 2400 baud 1 - 2743 baud (N/A) 2 - 2800 baud (N/A) 3 - 3000 baud 4 - 3200 baud 5 - 3429 baud (N/A until V.34bis) Default: 0 (2400 baud) 36 Reserved 37 Line connection speed 0 - Attempt to connect at the highest speed 3 - Attempt to connect at 300 bps 4 - Attempt to connect at 1200 bps 6 - Attempt to connect at 2400 bps 7 - Attempt to connect at 4800 bps 8 - Attempt to connect at 7200 bps 9 - Attempt to connect at 9600 bps 10 - Attempt to connect at 12000 bps 11 - Attempt to connect at 14400 bps 12 - Attempt to connect at V.34 13 - Attempt to connect at 56K 14 - Attempt to connect at V.90 Default: 0 38 Delay before forced hang up Set the delay to hang up after the disconnecting command is received. Range: 0 - 255 Milliseconds Default: 20 Milliseconds 39 Reserved 24 V90K56DOCATC11A

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

24
AT Command Guide
V90K56DOCATC11A
34
V.90 data rate (bit-rate)
Set the maximum bit rate for V.90
Range: 0-21
bit rate = 28000 + S34 * 1333bps
K56Flex data rate (bit-rate)
Set the maximum bit rate for 56K
Range: 0-12
bit rate = 32000bps + S34 * 2000bps
V.34 data rate (bit-rate)
Set the maximum bit rate for V.34
Range : 0-8 (2400 baud)
bit rate = ((S34)+1) * 2400bps
Default:
21
(33600 bps)
35
V.34 symbol rate (baud-rate)
Set the maximum baud rate for V.34
Range: 0-5
0 - 2400 baud
1 - 2743 baud (N/A)
2 - 2800 baud (N/A)
3 - 3000 baud
4 - 3200 baud
5 - 3429 baud (N/A until V.34bis)
Default:
0
(2400 baud)
36
Reserved
37
Line connection speed
0 - Attempt to connect at the highest speed
3 - Attempt to connect at 300 bps
4 - Attempt to connect at 1200 bps
6 - Attempt to connect at 2400 bps
7 - Attempt to connect at 4800 bps
8 - Attempt to connect at 7200 bps
9 - Attempt to connect at 9600 bps
10 - Attempt to connect at 12000 bps
11 - Attempt to connect at 14400 bps
12 - Attempt to connect at V.34
13 - Attempt to connect at 56K
14 – Attempt to connect at V.90
Default:
0
38
Delay before forced hang up
Set the delay to hang up after the disconnecting command is received.
Range: 0 - 255 Milliseconds
Default:
20
Milliseconds
39
Reserved