HP ProDesk 400 G5 Micro Maintenance and Service Guide 1 - Page 51

Fan-sink, Release the power supply P3 cable from the two retention clips

Page 51 highlights

Fan-sink NOTE: The fan-sink spare park kit includes replacement thermal material. Follow these steps to remove the fan-sink: 1. Prepare the computer for disassembly (see Preparation for disassembly on page 28). 2. Remove the access panel (see Access panel on page 29). 3. Remove the front bezel (see Front bezel on page 32). 4. Remove the drive cage (see Drive cage on page 33). Remove the fan-sink: 1. Disconnect the fan-sink cable (1) from the system board. 2. Release the power supply P3 cable from the two retention clips (2) built into the fan-sink. 3. Loosen the four slotted Torx-15 captive screws (3) that secure the fan-sink to the computer chassis. NOTE: Due to the adhesive nature of the thermal material located between the fan-sink and the processor, it may be necessary to move the fan-sink from side to side when removing the it. 4. Remove the fan-sink (4). Reverse this procedure to install the fan-sink. Fan-sink 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Fan-sink
NOTE:
The fan-sink spare park kit includes replacement thermal material.
Follow these steps to remove the fan-sink:
1.
Prepare the computer for disassembly (see
Preparation for disassembly
on page
28
).
2.
Remove the access panel (see
Access panel
on page
29
).
3.
Remove the front bezel (see
Front bezel
on page
32
).
4.
Remove the drive cage (see
Drive cage
on page
33
).
Remove the fan-sink:
1.
Disconnect the fan-sink cable
(1)
from the system board.
2.
Release the power supply P3 cable from the two retention clips
(2)
built into the fan-sink.
3.
Loosen the four slotted Torx-15 captive screws
(3)
that secure the fan-sink to the computer chassis.
NOTE:
Due to the adhesive nature of the thermal material located between the fan-sink and
the processor, it may be necessary to move the fan-sink from side to side when removing the it.
4.
Remove the fan-sink
(4)
.
Reverse this procedure to install the fan-sink.
Fan-sink
43