HP ProLiant BL620c HP ProLiant Servers Troubleshooting Guide - Page 133

Series, Series

Page 133 highlights

2. Run Insight Diagnostics ("HP Insight Diagnostics" on page 75) and replace failed components as indicated. 400 Series 40X-Parallel Port X Address Assignment Conflict Audible Beeps: 2 short Possible Cause: Both external and internal ports are assigned to parallel port X. Action: Run the server setup utility and correct the configuration. 404-Parallel Port Address Conflict Detected... ...A hardware conflict in your system is keeping some system components from working correctly. If you have recently added new hardware remove it to see if it is the cause of the conflict. Alternatively, use Computer Setup or your operating system to insure that no conflicts exist. Audible Beeps: 2 short Possible Cause: A hardware conflict in the system is preventing the parallel port from working correctly. Action: 1. If you have recently added new hardware, remove it to see if the hardware is the cause of the conflict. 2. Run the server setup utility to reassign resources for the parallel port and manually resolve the resource conflict. 3. Run Insight Diagnostics ("HP Insight Diagnostics" on page 75) and replace failed components as indicated. 600 Series 601-Diskette Controller Error Audible Beeps: None Possible Cause: Diskette controller circuitry failure occurred. Action: 1. Be sure the diskette drive cables are connected. 2. Replace the diskette drive, the cable, or both. 3. Run Insight Diagnostics ("HP Insight Diagnostics" on page 75) and replace failed components as indicated. 602-Diskette Boot Record Error Audible Beeps: None Possible Cause: The boot sector on the boot disk is corrupt. Action: 1. Remove the diskette from the diskette drive. Error messages 133

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

Error messages 133
2.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
75
) and replace failed components as
indicated.
400 Series
40X-Parallel Port X Address Assignment Conflict
Audible Beeps
: 2 short
Possible Cause
: Both external and internal ports are assigned to parallel port
X
.
Action
: Run the server setup utility and correct the configuration.
404-Parallel Port Address Conflict Detected...
...A hardware conflict in your system is keeping some system components from working correctly. If you have
recently added new hardware remove it to see if it is the cause of the conflict. Alternatively, use Computer Setup or
your operating system to insure that no conflicts exist.
Audible Beeps
: 2 short
Possible Cause
: A hardware conflict in the system is preventing the parallel port from working correctly.
Action
:
1.
If you have recently added new hardware, remove it to see if the hardware is the cause of the
conflict.
2.
Run the server setup utility to reassign resources for the parallel port and manually resolve the
resource conflict.
3.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
75
) and replace failed components as
indicated.
600 Series
601-Diskette Controller Error
Audible Beeps
: None
Possible Cause
: Diskette controller circuitry failure occurred.
Action
:
1.
Be sure the diskette drive cables are connected.
2.
Replace the diskette drive, the cable, or both.
3.
Run Insight Diagnostics ("
HP Insight Diagnostics
" on page
75
) and replace failed components as
indicated.
602-Diskette Boot Record Error
Audible Beeps
: None
Possible Cause
: The boot sector on the boot disk is corrupt.
Action
:
1.
Remove the diskette from the diskette drive.