HP ProLiant DL360e HP ROM-Based Setup Utility User Guide - Page 136

System, Options > SATA Controller Options, Enabled, Disabled, Drive Write Cache - gen8 raid

Page 136 highlights

Drive Write Cache NOTE: This option is available on G7 servers. For Gen8 servers, this option is in under System Options > SATA Controller Options ("Drive Write Cache" (page 39)) The Drive Write Cache option controls the state of the write cache of the drives attached to the supported controller. This feature provides greater drive performance but could result in data corruption during an unexpected power loss or shutdown. This option only affects operation for fixed drives attached to the embedded SATA controller when not operating in a software RAID mode. This option has no effect if fixed drives are attached to an embedded or optional Smart Array controller or if the Smart Array B110i Software RAID solution is used. CAUTION: Enabling Drive Write Cache may result in data loss or data corruption if an unexpected power loss occurs. After pressing any key to clear the warning, the following options are displayed: • Enabled • Disabled (default) 136 RBSU menu-driven interface (G7 and later servers)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204

Drive Write Cache
NOTE:
This option is available on G7 servers. For Gen8 servers, this option is in under
System
Options > SATA Controller Options
(
“Drive Write Cache” (page 39)
)
The Drive Write Cache option controls the state of the write cache of the drives attached to the
supported controller. This feature provides greater drive performance but could result in data
corruption during an unexpected power loss or shutdown.
This option only affects operation for fixed drives attached to the embedded SATA controller when
not operating in a software RAID mode. This option has no effect if fixed drives are attached to
an embedded or optional Smart Array controller or if the Smart Array B110i Software RAID solution
is used.
CAUTION:
Enabling Drive Write Cache may result in data loss or data corruption if an unexpected
power loss occurs.
After pressing any key to clear the warning, the following options are displayed:
Enabled
Disabled
(default)
136
RBSU menu-driven interface (G7 and later servers)