HP ProLiant ML310e HP Scripting Toolkit 9.30 for Linux User Guide - Page 47

HBA_WW_ID, HostMode, ACU scripting error messages, Microsoft Windows

Page 47 highlights

The string can consist of the following: • A maximum of 16 characters • Embedded space characters but cannot end with a space character • Any of the following characters: a-z, A-Z, 0-9 and [space] HBA_WW_ID This option specifies which HBA, based on its assigned WWN, is modified by the configuration changes. HostMode This option specifies the HostMode for a selected HBA. Setting the Host Mode optimizes the storage array for the selected operating system. The available host modes for an HBA are device-specific. Not all modes are available on all devices. Not all HBAs support a HostMode. The following operating system options might be available: • Default • Microsoft Windows • OpenVMS • Tru64 • Linux • Solaris • Netware • HP-UX ACU scripting error messages Error code Error message Comment or clarification 1 General error. The ACU process cannot be initiated. You might see this error message if you are not authenticated to use ACU or if ACU is already running. 268 Error saving controller. ACU cannot save one or more controller configurations. 278-282 Controller is locked by another machine or - user. 290 Error communicating with controller. - 516 Internal error. An error occurred during the configuration process, but ACU cannot identify the error because there is an internal ACU error. 1052 Array requires an odd number of drives. This error message occurs if you attempt to add an odd number of drives to an array that has RAID 1 logical drives, and the controller does not support RAID-level migration. 1053 Cannot remove physical drives from existing array. This error message occurs if a script that is running in Reconfigure action mode lists fewer physical drives than already exist in the array. ACU interprets this script as a request to remove physical drives from an existing array, but satisfying this request causes data loss, so ACU prevents the script from running. 1065-1066 Too many coinciding expansion, migration, ACU does not support multiple simultaneous expansions, or extension operations. migrations, or extensions without saving the configuration Using HPACUSCRIPTING 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

The string can consist of the following:
A maximum of 16 characters
Embedded space characters but cannot end with a space character
Any of the following characters: a–z, A–Z, 0–9, !, @, #, *, (, ), -, _, +, :, ., /, and [space]
HBA_WW_ID
This option specifies which HBA, based on its assigned WWN, is modified by the configuration
changes.
HostMode
This option specifies the HostMode for a selected HBA. Setting the Host Mode optimizes the storage
array for the selected operating system. The available host modes for an HBA are device-specific.
Not all modes are available on all devices. Not all HBAs support a HostMode.
The following operating system options might be available:
Default
Microsoft Windows
OpenVMS
Tru64
Linux
Solaris
Netware
HP-UX
ACU scripting error messages
Comment or clarification
Error message
Error code
The ACU process cannot be initiated. You might see this error
message if you are not authenticated to use ACU or if ACU
is already running.
General error.
1
ACU cannot save one or more controller configurations.
Error saving controller.
268
Controller is locked by another machine or
user.
278-282
Error communicating with controller.
290
An error occurred during the configuration process, but ACU
cannot identify the error because there is an internal ACU
error.
Internal error.
516
This error message occurs if you attempt to add an odd
number of drives to an array that has RAID 1 logical drives,
and the controller does not support RAID-level migration.
Array requires an odd number of drives.
1052
This error message occurs if a script that is running in
Reconfigure action mode lists fewer physical drives than
Cannot remove physical drives from
existing array.
1053
already exist in the array. ACU interprets this script as a
request to remove physical drives from an existing array, but
satisfying this request causes data loss, so ACU prevents the
script from running.
ACU does not support multiple simultaneous expansions,
migrations, or extensions without saving the configuration
Too many coinciding expansion, migration,
or extension operations.
1065-1066
Using HPACUSCRIPTING