HP ProLiant WS460c HP Smart Update Manager 5.3.5 User Guide - Page 44

Component configuration for Windows components only, Command-line examples, Smart Array controller

Page 44 highlights

: HP SUM does not install any updates when you generate a report. Using input files /inputfile "filename" /deleteinputfile Description Enables you to script the deployment of firmware and software to multiple remote systems at one time. For more information, see "Input files" (page 48). Enables you to instruct HP SUM to delete the input file after it has been read. Superdome 2 server commands /update_type /device_list /reboot_list Description Determines which Superdome 2 firmware is updated. You can choose ALL, COMPLEX, or PARTITIONS. The default selection is ALL. Example: /update_type PARTITIONS Use this argument when the /update_type argument is PARTITIONS. This argument specifies the subset of partitions or blades to update when you do not want to update all partitions or blades. Valid devices are: npar(number) and blade(enc)/(bay). Do not put any spaces between the parameters. Example: /device_list npar1,npar2,blade1/1,blade1/2 Use this argument when the /update_type is ALL or PARTITIONS. This argument specifies specific partitions to reboot after the partition firmware has been updated. Valid npar values are npar(number). Do not put any spaces between parameters. Example: /reboot_list npar1,npar2 Component configuration for Windows components only To configure components without using the HP SUM GUI, issue the command hpsum_config. This command presents the same configuration screens that appear in the HP SUM GUI. Run this command from a writeable media source. Configuration for a given component must be executed only one time. The configuration is stored within the component and is propagated to all target servers when it is deployed through the HP SUM GUI or a command line. To change the configuration, rerun hpsum_config against the component. If a component does not need configuration, the hpsum_config command returns to the console. To configure components to be deployed on all editions of Windows Server 2008 with the Server Core option, you must access the system as a remote host by using HP SUM running on a system with a supported Windows operating system, and then configure the components before deployment. Command-line examples The following command-line parameter examples can be executed within these environments: • Firmware: ◦ System ROM ◦ Smart Array controller 44 Using scripts to deploy updates

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

:
HP SUM does not install any updates when you generate a report.
Description
Using input files
Enables you to script the deployment of firmware and
software to multiple remote systems at one time. For more
information, see
“Input files” (page 48)
.
/inputfile
“filename”
Enables you to instruct HP SUM to delete the input file after
it has been read.
/deleteinputfile
Description
Superdome 2 server commands
Determines which Superdome 2 firmware is updated. You
can choose
ALL
,
COMPLEX
, or
PARTITIONS
. The default
selection is
ALL
.
/update_type
<type>
Example:
/update_type PARTITIONS
Use this argument when the
/update_type
argument is
PARTITIONS
. This argument specifies the subset of
/device_list
<device[,device]…>
partitions or blades to update when you do not want to
update all partitions or blades. Valid devices are:
npar(number)
and
blade(enc)/(bay)
. Do not put
any spaces between the parameters.
Example:
/device_list
npar1,npar2,blade1/1,blade1/2
Use this argument when the
/update_type
is
ALL
or
PARTITIONS
. This argument specifies specific partitions
/reboot_list
<npar[,npar]…>
to reboot after the partition firmware has been updated.
Valid
npar
values are
npar(number)
. Do not put any
spaces between parameters.
Example:
/reboot_list npar1,npar2
Component configuration for Windows components only
To configure components without using the HP SUM GUI, issue the command
hpsum_config<component_to_configure>
. This command presents the same configuration
screens that appear in the HP SUM GUI. Run this command from a writeable media source.
Configuration for a given component must be executed only one time. The configuration is stored
within the component and is propagated to all target servers when it is deployed through the HP
SUM GUI or a command line. To change the configuration, rerun
hpsum_config
against the
component. If a component does not need configuration, the
hpsum_config
command returns
to the console.
To configure components to be deployed on all editions of Windows Server 2008 with the Server
Core option, you must access the system as a remote host by using HP SUM running on a system
with a supported Windows operating system, and then configure the components before deployment.
Command-line examples
The following command-line parameter examples can be executed within these environments:
Firmware:
System ROM
Smart Array controller
44
Using scripts to deploy updates