HP Scitex FB10000 Geffen TS Error 66117 - Page 1

HP Scitex FB10000 Manual

Page 1 highlights

Error ID: 66117: Unified Cooler - Water Overflow FB10000 Error Messages Troubleshooting Error ID: 66117: Unified Cooler - Water Overflow Error Severity: Warning Possible Causes • Water Level over the Overflow mark • Faulty Overflow LED • Faulty Overflow Sensor • Faulty J1 connector Recommended Actions 1. Visually check the water level in the Unified Cooler water level indicator. Overflow LED Overflow mark Drain valve Cooler Water Level Indicator FB10000 Error Messages Troubleshooting

  • 1
  • 2
  • 3
  • 4

Error ID: 66117: Unified Cooler – Water Overflow
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 66117: Unified Cooler – Water Overflow
Error Severity:
Warning
Possible Causes
Water Level over the Overflow mark
Faulty Overflow LED
Faulty Overflow Sensor
Faulty J1 connector
Recommended Actions
1.
Visually check the water level in the Unified Cooler water level indicator.
Cooler Water Level Indicator
Overflow mark
Overflow LED
Drain valve