Overflow sensor, J1 Molex, connector, Unified Cooler Overflow Sensor and J1 Connector

Page 4 highlights

Error ID: 66117: Unified Cooler - Water Overflow Overflow sensor Troubleshooting J1 Molex connector Unified Cooler Overflow Sensor and J1 Connector 11. If there is continuity on the cable side but not on the sensor side, the error was probably triggered by a faulty Connector - In this case, replace the J1 connector. 12. If all these steps did not solve the problem, contact your HP regional technical specialist. 4

  • 1
  • 2
  • 3
  • 4

Error ID: 66117: Unified Cooler – Water Overflow
Troubleshooting
4
Unified Cooler Overflow Sensor and J1 Connector
11.
If there is continuity on the cable side but not on the sensor side, the error was probably triggered by a faulty Connector – In this case,
replace the J1 connector.
12.
If all these steps did not solve the problem, contact your HP regional technical specialist.
Overflow sensor
J1 Molex
connector