HP Scitex FB10000 Geffen TS Error 66008 - Page 9

Turn the machine on and let the B&R control PLC automatically con the new Bus Unit.

Page 9 highlights

Error ID: 66008: IDS - Overflow in cyan main tank. FB10000 Error Messages Troubleshooting Top Flowchart 2. Before replacing a module BU, turn the machine power OFF. 3. Release the module terminal block with its wires, as shown below. 4. Pull the module Bus Unit of its base and replace it by a new one. 5. Plug back the terminal block into the Bus Unit until you hear a click. Upon turning the machine on, the R/E led will blink green once, signaling that it has detected the new BU. Step 1: Press the latch (1) on top of the TB (2) and unplug the TB from the BU to which it is attached. Step 2: Press the latch (5) on top of the BU (3) and unplug it from its base (4). Step 3: Plug the new BU (3) into its base (4). Step 4: Plug back the TB (2) into the new Bus Unit (3) until you hear a click. 6. Turn the machine on and let the B&R control PLC automatically configure the new Bus Unit. Note: This procedure takes up to two minutes. However, when the PLC encounters internal errors, it runs a full system scan and resets the entire system. This procedure takes between 40 to 60 minutes. If the PLC LED continues blinking orange once every 5 seconds this indicates that it failed to configure the new module. If none of the above steps solved the problem, contact your HP service specialist. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Error ID: 66008: IDS - Overflow in cyan main tank.
FB10000 Error Messages Troubleshooting
2.
Before replacing a module BU, turn the machine power OFF.
3.
Release the module terminal block with its wires, as shown below.
4.
Pull the module Bus Unit of its base and replace it by a new one.
5.
Plug back the terminal block into the Bus Unit until you hear a click.
Upon turning the machine on, the R/E led will blink green once, signaling that it has detected the new BU.
6.
Turn the machine on and let the B&R control PLC automatically configure the new Bus Unit.
Note: This procedure takes up to two minutes. However, when the PLC encounters internal errors, it runs a full system scan and resets
the entire system. This procedure takes between 40 to 60 minutes. If the PLC LED continues blinking orange once every 5
seconds this indicates that it failed to configure the new module.
If none of the above steps solved the problem, contact your HP service specialist.
Step 1: Press the latch (1) on top of the TB (2) and unplug
the TB from the BU to which it is attached.
Step 2: Press the latch (5) on top of the BU (3) and unplug it
from its base (4).
Step 3: Plug the new BU (3) into its base (4).
Step 4: Plug back the TB (2) into the new Bus Unit (3)
until you hear a click.
Top
Flowchart
9