HP Scitex FB10000 Geffen TS Error 50071 - Page 1
HP Scitex FB10000 Manual
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
Error ID: 50071 - Motion - X-Axis unable to move FB10000 Error Messages Troubleshooting Error ID: 50071 - Motion - X-Axis unable to move Error Message: 50071 X-Axis unable to move. Verify that the waste bath is up and in its cradle, vacuum knife is at home (operator side), and the Loader and Unloader beams are not in their lower position For more details open the Troubleshooting guide Possible Causes • Bath is not up and not in its place • Wiper is not at home position • L&U axes are not at their lower limits 1 FB10000 Error Messages Troubleshooting
Error ID: 50071 - Motion – X-Axis unable to move
FB10000 Error Messages Troubleshooting
FB10000 Error Messages Troubleshooting
Error ID: 50071 - Motion – X-Axis unable to move
Error Message:
50071 <Month, Day, Time>
X-Axis unable to move. Verify that the waste bath is up and in its
cradle, vacuum knife is at home (operator side), and the Loader and
Unloader beams are not in their lower position For more details open
the
Troubleshooting guide
Possible Causes
•
Bath is not up and not in its place
•
Wiper is not at home position
•
L&U axes are not at their lower limits