HP Scitex FB10000 Geffen TS Error 50099 - Page 2
Recommended actions, Mechanical block, Sensor problem
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 2 highlights
Error ID: 50099 - MH - Failed to move inlet Middle-Check fence down Recommended actions Mechanical block 1. Move the ML table away from the machine 2. Inspect the pistons to ensure that they are not mechanically blocked. 3. Inspect the fence to ensure that it is not mechanically blocked. Sensor problem 1. Remove the Multiload table from the machine. 2. Make sure that the sensors are well connected to their Molex plugs. 3. Visually inspect the sensors to ensure that they their red LED is ON, if the LES is OFF, use a small flathead screw driver to release the sensor's set screw and slowly slide it along the piston until the LED is ON, then fasten the screw to secure the sensor in its correct position. 2 FB10000 Error Messages Troubleshooting Top