HP Scitex FB10000 Geffen TS Error 50099 - Page 4

Pneumatic fault (step 5 is for HP CE only)

Page 4 highlights

Error ID: 50099 - MH - Failed to move inlet Middle-Check fence down Pneumatic fault (step 5 is for HP CE only) 1. Make sure that all the tubes are well connected to the pistons' fittings 2. Make sure that the tubes are mot kinked or pinched along their path 3. Make sure that the main air pressure is set to 6-8 Bar 4. Make sure that the Loader pneumatic panel has air pressure (see the 4 gauges for indication) FB10000 Error Messages Troubleshooting Top • Remove the panel covering the loader pneumatic panel and make sure that air pressure is coming in and out freely to and from Fence 1 and Fence 2 units. You can perform this check by activating the fence via Control Tools. 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

Error ID: 50099 – MH – Failed to move inlet Middle-Check fence down
FB10000 Error Messages Troubleshooting
Pneumatic fault (step 5 is for HP CE only)
1.
Make sure that all the tubes are well connected to the pistons’ fittings
2.
Make sure that the tubes are mot kinked or pinched along their path
3.
Make sure that the main air pressure is set to 6-8 Bar
4.
Make sure that the Loader pneumatic panel has air pressure (see the 4 gauges for indication)
Remove the panel covering the loader pneumatic panel and make sure that air pressure is coming in and out freely to and from Fence
1 and Fence 2 units. You can perform this check by activating the fence via Control Tools.
Top
4