Error ID: 66049: Cyan cross valve front failed to close FB10000 Error Messages Troubleshooting FB10000 Error Messages Troubleshooting Error ID: 66049: Cyan cross valve front failed to close Error Severity: Critical Possible Causes • Cross valves sensors do not receive 24V supply • Feeding valve in Bridge Pneumatic panel does not supply air pressure to cross valves • Main Valve in Main Pneumatic panel does not supply air pressure to feeding valve in bridge pneumatic panel • One or more cross valve(s) are mechanically stuck • One or more cross valve sensor(s) is faulty • B&R module 1DO2 in LEC is faulty • One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty Troubleshooting Flowchart 1
Error ID: 66049: Cyan cross valve front failed to close
FB10000 Error Messages Troubleshooting
1
FB10000 Error Messages Troubleshooting
Error ID: 66049: Cyan cross valve front failed to close
Error Severity:
Critical
Possible Causes
•
Cross valves
sensors
do not receive 24V supply
•
Feeding valve in Bridge Pneumatic panel does not supply air pressure to cross valves
•
Main Valve in Main Pneumatic panel does not supply air pressure to feeding valve in bridge pneumatic panel
•
One or more cross valve(s) are mechanically stuck
•
One or more cross valve sensor(s) is faulty
•
B&R module 1DO2 in LEC is faulty
•
One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty
Troubleshooting Flowchart