HP Scitex FB10000 Geffen TS Error 66049 - Page 5
One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 5 highlights
Error ID: 66049: Cyan cross valve front failed to close One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty FB10000 Error Messages Troubleshooting 1. If only one sensor shows error this might be a sensor problem. 2. If two sensors belonging to following couples (LC+LM , Y+C , M+K) shows error, this might indicate a problem in one of the BR modules on the bridge because these couples are twin connected in the Bridge B&R modules as shown in the diagram below. Flowchart Top 5
Error ID: 66049: Cyan cross valve front failed to close
FB10000 Error Messages Troubleshooting
5
One of the B&R modules 6DI1, 6DI2, 6DI3 on the bridge is faulty
1.
If only one sensor shows error this might be a sensor problem.
2.
If two sensors belonging to following couples (LC+LM
,
Y+C , M+K) shows error, this might indicate a problem in one of the BR modules on the
bridge because these couples are twin connected in the Bridge B&R modules as shown in the diagram below.
Top
Flowchart