HP Scitex FB10000 Geffen TS Error 50215 - Page 3

DI3171

Page 3 highlights

Error ID: 50215 - Motion - Cannot load media. Loader 2 (REC side) is at the lower sensor FB10000 Error Messages Troubleshooting 1. Make sure that the sensor is well connected to the Molex plug. 2. Make sure that the lower sensor is functioning. The LED should be OFF once the sensor is triggered (i.e. use a spacer to trigger the sensor). Top 3. Make sure that cable CX161-03850 is well connected to B&R Module 8DI2 (input #3) attached to the back of the dynamic loader (see cable label DI3171 2-3). 3

  • 1
  • 2
  • 3
  • 4
  • 5

Error ID: 50215 – Motion – Cannot load media. Loader 2 (REC side) is at the lower sensor
FB10000 Error Messages Troubleshooting
1.
Make sure that the sensor is well connected to the Molex plug.
2.
Make sure that the lower sensor is functioning. The LED should be OFF once the sensor is triggered (i.e. use a spacer to trigger the
sensor).
3.
Make sure that cable CX161-03850 is well connected to B&R Module 8DI2 (input #3) attached to the back of the dynamic loader
(see cable label
DI3171
2-3
).
Top
3