Error ID: 50215 - Motion - Cannot load media. Loader 2 (REC side) is at the lower sensor Mechanical Problem 1. Make sure that the pulleys are fastened to their shafts. 2. Make sure that the pulleys are rotating freely. 3. Make sure that the belt is tight. 4. Make sure that the lead-screw is not damaged or worn out. FB10000 Error Messages Troubleshooting Top Warning! Motor synchronization should be done exclusively by a certified HP Service Engineer! Motors Synchronization 1. Follow the instructions provided in the 'Verifying the Height and of the Loader and Unloader Bars' section in the FB10000 Installation Manual. 5

  • 1
  • 2
  • 3
  • 4
  • 5

Error ID: 50215 – Motion – Cannot load media. Loader 2 (REC side) is at the lower sensor
FB10000 Error Messages Troubleshooting
Mechanical Problem
1.
Make sure that the pulleys are fastened to their shafts.
2.
Make sure that the pulleys are rotating freely.
3.
Make sure that the belt is tight.
4.
Make sure that the lead-screw is not damaged or worn out.
Warning! Motor synchronization should be done exclusively by a certified HP Service Engineer!
Motors Synchronization
1.
Follow the instructions provided in the ‘
Verifying the Height and of the Loader and Unloader Bars’ section in the FB10000 Installation Manual.
Top