HP Scitex FB10000 Geffen TS Error 1103 - Page 1

HP Scitex FB10000 Manual

Page 1 highlights

Error ID: 1103: IDS - Unable to connect or read smart chip on waste tank FB10000 Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 1103: IDS - Unable to connect or read smart chip on waste tank This error indicates that the Moby of the waste container failed to communicate with the waste container. Error Severity: Critical Possible Causes • Ink container smart chip is misaligned, missing or faulty • Moby pins are bent or dirty • Moby cable is disconnected or faulty • Spider board needs to be reset or is faulty and must be replaced 1

  • 1
  • 2
  • 3

Error ID: 1103: IDS – Unable to connect or read smart chip on waste tank
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 1103: IDS – Unable to connect or read smart chip on waste tank
This error indicates that the Moby of the waste container failed to communicate with the waste container.
Error Severity:
Critical
Possible Causes
Ink container smart chip is misaligned, missing or faulty
Moby pins are bent or dirty
Moby cable is disconnected or faulty
Spider board needs to be reset or is faulty and must be replaced
1