Error ID: 1103: IDS - Unable to connect or read smart chip on waste tank FB10000 Error Message Troubleshooting FB10000 Error Message Troubleshooting Error ID: 1103: IDS - Unable to connect or read smart chip on waste tank This error indicates that the Moby of the waste container failed to communicate with the waste container. Error Severity: Critical Possible Causes • Ink container smart chip is misaligned, missing or faulty • Moby pins are bent or dirty • Moby cable is disconnected or faulty • Spider board needs to be reset or is faulty and must be replaced 1
Error ID: 1103: IDS – Unable to connect or read smart chip on waste tank
FB10000 Error Message Troubleshooting
FB10000 Error Message Troubleshooting
Error ID: 1103: IDS – Unable to connect or read smart chip on waste tank
This error indicates that the Moby of the waste container failed to communicate with the waste container.
Error Severity:
Critical
Possible Causes
•
Ink container smart chip is misaligned, missing or faulty
•
Moby pins are bent or dirty
•
Moby cable is disconnected or faulty
•
Spider board needs to be reset or is faulty and must be replaced