HP Scitex FB10000 Geffen TS Error 66062 - Page 6
Magenta secondary tank feeding pump or wiring is faulty, If the error persists
![]() |
View all HP Scitex FB10000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 6 highlights
Error ID: 60062 - IDS - Unable to fill the Magenta secondary tank (timed out) FB10000 Error Message Troubleshooting Magenta secondary tank feeding pump or wiring is faulty 1. If the corresponding B&R and its wiring are Ok and the command still does not activate the feeding secondary tank pump, try replacing the secondary tank feeding pump. 2. If after replacing the pump, the error persists, check the Magenta ink tubing to the Magenta secondary tank. Magenta 3 Way-switching valve is faulty 1. Replace the valve if faulty. 2. If the error persists, contact callme@hp for specialist assistance. Top 6
![](/manual_guide/products/hewlettpackard-scitex-fb10000-geffen-ts-error-66062-de45359/6.png)
Error ID: 60062 – IDS – Unable to fill the Magenta secondary tank (timed out)
FB10000 Error Message Troubleshooting
Magenta secondary tank feeding pump or wiring is faulty
1.
If the corresponding B&R and its wiring are Ok and the command still does not activate the feeding secondary tank pump, try replacing
the secondary tank feeding pump.
2.
If after replacing the pump, the error persists, check the Magenta ink tubing to the Magenta secondary tank.
Magenta 3 Way-switching valve is faulty
1.
Replace the valve if faulty.
2.
If the error persists, contact callme@hp for specialist assistance.
Top
6