HP StorageWorks 2/128 Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 57
Configuring Fabric Watch Thresholds, Changing the Threshold Boundary Level
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
Configuring Fabric Watch Thresholds 3 Figure 3-2 shows how to change the threshold boundary level to custom so that the new custom value of 80 is the new trigger point. Figure 3-3 shows how to apply the custom value; unless you apply the value, it does not take effect. 1 : change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change belowalarm 4 : change custom unit 14 : change abovealarm 5 : change custom timebase 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18]3 1 : Default 2 : custom Enter boundary level type => : (1..2) [1] 2 Index ThresholdName 216 eportRXPerf216 217 eportRXPerf217 218 eportRXPerf218 219 eportRXPerf219 220 eportRXPerf220 221 eportRXPerf221 222 eportRXPerf222 223 eportRXPerf223 BehaviorType Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 Triggered 1 BehaviorInt Threshold boundary level is set at : Custom. . . . Figure 3-2 Changing the Threshold Boundary Level 1 : change behavior type 11 : change threshold alarm level 2 : change behavior interval 12 : change changed alarm 3 : change threshold boundary level 13 : change belowalarm 4 : change custom unit 14 : change abovealarm 5 : change custom timebase 15 : change inBetween alarm 6 : change custom low 16 : apply threshold alarm changes 7 : change custom high 17 : cancel threshold alarm changes 8 : change custom buffer 18 : return to previous page 9 : apply threshold boundary changes 10 : cancel threshold boundary changes Select choice => : (1..18) [18]9. . . Figure 3-3 Applying Threshold Boundary Changes Note To ensure that your threshold setting configuration takes effect, remember to apply the threshold boundary changes, and then change the threshold boundary level to Custom. Fabric Watch Administrator's Guide 3-9 Publication Number: 53-1000243-01