HP StorageWorks 2/128 Brocade Fabric Watch Administrator's Guide (53-1000243-0 - Page 92
Environment Class, Default Threshold Values, Environment Class Threshold Defaults
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 92 highlights
A Default Threshold Values Environment Class Table A-1 provides default settings for areas in the Environment class. These defaults are hardwaredependent. Check the appropriate hardware reference manual for differences in environmental requirements. Note For the SilkWorm 200E, there is no fan default threshold because the fans are not monitored by Fabric Watch. You can use the fanShow command to view the SilkWorm 200E fan status (OK or NOT OK). However, you cannot use the fwConfigure command to manipulate the threshold or alarm actions against any fans. Table A-1 Area Fan Environment Class Threshold Defaults Description Default Threshold Settings Monitors switch fan Unit: RPM speed in RPMs Time Base: none SilkWorm 3850 and 3250 Low: 4500 High: 11000 Buffer: 3 SilkWorm 3900 Low: 2600 High: 10000 Buffer: 3 SilkWorm 4100 Low: 3000 High: 12000 Buffer: 3 SilkWorm 4900 Low: 4100 High: 8500 Buffer: 3 SilkWorm 7500 Low: 5000 High: 16000 Buffer: 3 SilkWorm 24000 Low: 1600 High: 3400 Buffer: 3 SilkWorm 48000 Low: 1600 High: 3400 Buffer: 3 Default Alarm Settings Changed: 0 Above: 3 Below: 3 In-Between: 1 Threshold State Informative Out_of_range Out_of_range In_range A-2 Fabric Watch Administrator's Guide Publication Number: 53-1000243-01