HP StorageWorks 2000i HP StorageWorks P2000 G3 MSA System Event Description Re - Page 26

snapshot in two stages.

Page 26 highlights

251 Warning A volume-copy operation has started for the indicated source volume. Recommended actions • If the source volume is a master volume, you can remount it. If the source volume is a snapshot, do not remount it until the copy is complete (as indicated by event 268). 252 Informational Snapshot write data on the indicated master volume has been deleted. Recommended actions • No action required. 253 Informational A license was uninstalled. Recommended actions • No action required. 255 Informational The PBCs across controllers do not match as PBC from controller A and PBC from controller B are from different vendors. This may limit the available configurations. Recommended actions • No action required. 256 Informational The indicated snapshot has been prepared but is not yet committed. This can occur when a snapshot is taken by an application, such as the VSS hardware provider, that is timing-sensitive and needs to take a snapshot in two stages. After the snapshot is committed and event 258 is logged, the snapshot can be used. Recommended actions • No action required. 257 Informational The indicated snapshot has been prepared and committed and is ready for use. Recommended actions • No action required. 258 Informational The indicated snapshot has been committed and is ready for use. Recommended actions • No action required. 259 Informational In-band CAPI commands have been disabled. Recommended actions • No action required. 260 Informational In-band CAPI commands have been enabled. Recommended actions • No action required. 26

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

26
251
Warning
A volume-copy operation has started for the indicated source volume.
Recommended actions
If the source volume is a master volume, you can remount it. If the source volume is a snapshot, do not
remount it until the copy is complete (as indicated by event 268).
252
Informational
Snapshot write data on the indicated master volume has been deleted.
Recommended actions
No action required.
253
Informational
A license was uninstalled.
Recommended actions
No action required.
255
Informational
The PBCs across controllers do not match as PBC from controller A and PBC from controller B are from
different vendors.
This may limit the available configurations.
Recommended actions
No action required.
256
Informational
The indicated snapshot has been prepared but is not yet committed. This can occur when a snapshot is
taken by an application, such as the VSS hardware provider, that is timing-sensitive and needs to take a
snapshot in two stages.
After the snapshot is committed and event 258 is logged, the snapshot can be used.
Recommended actions
No action required.
257
Informational
The indicated snapshot has been prepared and committed and is ready for use.
Recommended actions
No action required.
258
Informational
The indicated snapshot has been committed and is ready for use.
Recommended actions
No action required.
259
Informational
In-band CAPI commands have been disabled.
Recommended actions
No action required.
260
Informational
In-band CAPI commands have been enabled.
Recommended actions
No action required.