Step 4: Configure LCCs The disk system comes with two LCCs installed. If you are connecting this disk system to an HP StorageWorks Virtual Array 7400 or to a 1 Gb/s hub, the link speed switch must be set to 1 Gb/s. 1 Attach your ESD strap to ground. 2 Remove the LCC from the disk system chassis. Caution Do not touch the pins on the back of the LCC. 3 Set internal configuration dip switch to appropriate link speed. Be sure to set the internal LCC data transmission speed switch to 1 Gb/s or 2 Gb/s as appropriate for your configuration. See Figure 2.29 for more detailed information. 64 Installation
64
Installation
Step 4: Configure LCCs
The disk system comes with two LCCs installed.
If you are connecting this disk system to an HP StorageWorks Virtual Array 7400
or to a 1 Gb/s hub, the link speed switch must be set to 1 Gb/s.
1
Attach your ESD strap to ground.
2
Remove the LCC from the disk system chassis.
Caution
Do not touch the pins on the back of the LCC.
3
Set internal configuration dip switch to appropriate link speed.
Be sure to set the internal LCC data transmission speed switch to 1
Gb/s or 2 Gb/s as appropriate for your configuration. See Figure 2.29
for more detailed information.