HP StorageWorks 4/64 Brocade Error Message Reference Guide v6.0.0 (53-1000600- - Page 106
BL-1015, Recommended, Action, slotPowerOff, reboot, systemVerification, diagPost, Severity, Message
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
5 BL-1015 Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot the switch. Run the systemVerification command to determine if there is a hardware error. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade DCX, 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the Brocade 3900, replace the motherboard FRU. • On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500, AP7600, and 5000, replace the switch. Severity ERROR BL-1015 Message , [BL-1015], ,, ERROR, , bport port is faulted. status=0x. Probable Cause Indicates that the port generated an excessive number of interrupts that might prove fatal to the switch operation. The port is disabled to prevent the CP from becoming too busy. The bport is the blade port; this number might not correspond to a user port number. Recommended Action Make sure to capture the console output during this process. On a bladed switch, run the slotPowerOff and slotPowerOn commands. On a nonbladed switch, reboot the switch. Run the systemVerification command to determine if there is a hardware error. Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled. If there is a hardware error, if the slotPowerOff or slotPowerOn fails on the bladed switch or if errors are encountered again: • On the Brocade DCX, 24000, and 48000, replace the blade field-replaceable unit (FRU). • On the Brocade 3900, replace the motherboard FRU. • On the Brocade 200E, 3016, 3250, 3850, or 4100, 4012, 4016, 4018, 4024, 4900, 7500, AP7600, and 5000, replace the switch. Severity ERROR BL-1016 Message Probable Cause , [BL-1016], , FFDC, CRITICAL, , Blade port in slot failed to enable. Indicates that the specified blade port has failed to get enabled. 54 Fabric OS Message Reference 53-1000600-01