HP StorageWorks 4/64 Brocade Error Message Reference Guide v6.0.0 (53-1000600- - Page 459
SEC-1166, SEC-1167, SEC-1168
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 459 highlights
66 SEC-1166 SEC-1166 Message , [SEC-1166], ,, ERROR, , Non FCS tries to commit failover. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR SEC-1167 Message , [SEC-1167], ,, ERROR, , Another FCS failover is in process. Command terminated. Probable Cause Indicates that because another failover is already in progress, this failover attempt cannot proceed. Recommended Action Verify that the security event was planned. If the security event was planned, retry fabric configurations server (FCS) failover after current failover has completed, if this switch should become primary FCS. If the security event was not planned, take appropriate action as defined by your enterprise security policy. Severity ERROR SEC-1168 Message , [SEC-1168], ,, ERROR, , Primary FCS failover is busy. Please retry later. Probable Cause Indicates that there has been a corruption during the distribution of the security database. This can only occur when the primary fabric configurations server (FCS) is distributing the security database to the other switches in the fabric and local validation finds that there is an error in the security database. This is a rare occurrence. Recommended Action Run the secFabricShow command to verify that the fabric is still consistent. All the switches should be in the ready state. If a switch is in the error state, the database might not be correctly updated for that specific switch. Severity ERROR Fabric OS Message Reference 407 53-1000600-01