HP StorageWorks 4/64 Brocade Fabric OS MIB Reference (53-1000241-01, November - Page 148
swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2, Enterprise, Variables
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 148 highlights
5 swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2 Enterprise sw Variables "swDiagResult 1.3.6.1.4.1.1588.2.1.1.1.1.20" "swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10" A swFault is generated whenever the diagnostics detect a fault with the switch. #TYPE #SUMMARY #ARGUMENTS #SEVERITY #TIMEINDEX #STATE Switch is faulty. Faulty reason: %d and SSN is #%s 0, 1 Critical 1 Nonoperational swSensorScn 1.3.6.1.4.1.1588.2.1.1.1.0.2 (Obsoleted by swFabricWatchTrap) Enterprise sw Variables "swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3" "swSensorIndex 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.1" "swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2" "swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4" "swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5" "swSsn 1.3.6.1.4.1.1588.2.1.1.1.1.10" A swSensorScn (2) is generated whenever an environment sensor changes its operational state: for instance, if a fan stop working. The VarBind in the Trap Data Unit contain the corresponding instance of the sensor status, sensor index, sensor type, sensor value (reading), and sensor information. Note that the sensor information contains the type of sensor and its number, in textual format. #TYPE #SUMMARY #ARGUMENTS #SEVERITY #TIMEINDEX #STATE A sensor (temperature, fan, or other) changed its operational state. %s: is currently in state %d and SSN is #%s 4, 0, 5 Informational 1 Operational swFCPortScn 1.3.6.1.4.1.1588.2.1.1.1.0.3 Enterprise sw 5-14 Fabric OS MIB Reference Publication Number: 53-1000241-01