HP StorageWorks 8/40 HP StorageWorks Fabric OS 6.2.0e release notes (5697-0354 - Page 41
On an HP StorageWorks 8/80 SAN Switch, the system status LED
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
EE monitor counters may not get updated after performing switchdisable/switchenble or reboot. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Retrieve all EE monitors from the FLASH by issuing perfcfgrestore. All EE monitor counters will be properly updated. Static routing does not affect dynamic routes with DLS ON on supported platforms. Fixed in Fabric OS 6.2.0. The gzoneinfo.htm page returns empty data when CLI actually shows defined/eff cfg zone info for fabric. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Do any other HTTP post operation from DCFM and then you see both the old data and the newly pushed zone info. Rebooting the switch sometimes helps. Third-party storage center application does not survive in an FCIP network with 1% packet loss and 100 ms network latency. Fixed in Fabric OS 6.2.0. Traffic Isolation failover policy reverts back to disabled from enabled after changing the port membership list. Fixed in Fabric OS 6.2.0. Hareboot on HP StorageWorks 400 Multi-protocol Router FC Fast Write enabled switch causes the system to panic with "Oops: kernel access of bad area, sig: 11 [#1]." Fixed in Fabric OS 6.2.0. Fabric Mode TT displays redundant flows with different values for the same SID/DID pair on the core switches when there are redundant trunk groups to the same edge domain. Fixed in Fabric OS 6.2.0. DLS ON does not rebalance when ISLs to a different switch are removed on HP StorageWorks DC SAN Backbone Director and HP StorageWorks 8/80 SAN Switch. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Perform switchdisable and switchenable to force a rebalance of the routes. On an HP StorageWorks 8/80 SAN Switch, the system status LED does not flash amber/green when a power supply is faulted. Fixed in Fabric OS 6.2.0. User with admin role in some AD is able to add another user with admin role in AD as ALL. Fixed in Fabric OS 6.2.0. Reset to default button is grayed out always in SCSI vs. IP traffic setup window. Fixed in Fabric OS 6.2.0. USB Admin is not in sync with CLI when launched . It shows the correct info only when we click refresh button. Fixed in Fabric OS 6.2.0. Name Server database is being set with incorrect WWN's for NPIV nodes when port ALPA = 0x13. Fixed in Fabric OS 6.2.0. Workaround prior to upgrade: Port ALPA must be set to default value of 0x00 for ports hosting NPIV nodes. Potential timeouts and aborts during Device Discovery and CU busy processing when using FICON XRC Emulation. Fixed in Fabric OS 6.2.0. HP StorageWorks Fabric OS 6.2.0e release notes 41