HP StorageWorks 8/8 Brocade Fabric Watch Administrator's Guide v6.3.0 (53-1001 - Page 112
Environment class default settings, TABLE 16
View all HP StorageWorks 8/8 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
B Class default settings Environment class default settings Table 16 provides default Environment class settings for all switches. Check the appropriate hardware reference manual for differences in actual environmental requirements. NOTE Fabric Watch no longer supports fan monitoring. Event Manager (EM) now manages fan monitoring and the switch status is calculated based on the fan status reported by EM. TABLE 16 Area Environment class default settings Description Default threshold settings Temperature Monitors switch temperature in Celsius Unit: degrees C Time Base: none Brocade 200E Low: 0 High: 60 Buffer: 10 Brocade 300 Low: 0 High: 50 Buffer: 10 Brocade 4100 Low:0 High: 60 Buffer: 10 Brocade 4900 Low: 0 High: 47 Buffer: 10 Brocade 5000 Low:0 High: 60 Buffer: 10 Brocade 5100 Low: 0 High: 63 Buffer: 10 Brocade 5300 Low: 0 High: 48 Buffer: 10 Brocade 7500 Low: 0 High: 63 Buffer: 10 Brocade 7600 Low: 0 High: 63 Buffer: 10 Default alarm settings Threshold state Changed: 0 Below: 3 Above: 3 In-Between: 3 Informative Out-of-range Out-of-range In_range (Same setting for all (Same setting for all devices) devices except Brocade DCX-4S) 88 Fabric Watch Administrator's Guide 53-1001342-01